System Identification of Meloland Road Overcrossing
The Meloland Road Overcrossing (MRO) is a two-span reinforced concrete bridge structure located east of El Centro, California, 0.3 mi from the Imperial Fault. The Imperial Valley Earthquake...
System Identification of a Large Structure Using Pseudo-Dynamic Test Data
This paper deals with structural modeling and the determination of optimal nonlinear models by applying system identification techniques to inelastic pseudo-dynamic test data from a full-scale,...
Characteristics of a Structure-Foundation System
The dynamic characteristics of the structure-foundation system of a 1/4 -scale nuclear power plant containment model is studied using seismic records. The model structure is treated as...
Modal Parameter Identification of an Offshore Platform from Earthquake Response Records
The Whittier Narrows earthquake on October 1, 1987, was recorded by the earthquake monitoring system on an offshore platform installed in a water depth of 97 m in the Santa Barbara Channel....
Tradeoffs Between Active Control and Identification of Structural Systems
This paper explores the tradeoffs between structural identification and structural control in a quantitative manner. Through the intemediary concept of an optimal input, it is shown that...
Strong-Motion Records from Buildings
Since the establishment of the California Strong Motion Instrumentation Program in 1972, over 90 buildings have been instrumented extensively to measure their response during earthquakes....
Some Significant Records from Instrumented Structures in California?USGS Program
The main objective in seismic instrumentation of structures is to facilitate response studies that lead to improved understanding of the dynamic behavior and the potential for damage to...
Seismic Instrumentation and Its Implication for High-Rise Buildings in Japan
An outline of the present state of the strong earthquake motions observation systems in Japan and an example of the obtained records of an earthquake and its simulation analysis of a high-rise...
Seismic Evaluation of a Tall Reinforced Concrete Frame Building
Accelerations at basement, fifth and tenth floor levels of a reinforced concrete apartment building were recorded during the October 1st, 1987 Whittier-Narrows earthquake. These accelerations...
Architectural Configurations in Vina del Mar
This paper identifies the architectural characteristics of 121 reinforced concrete buildings in Vina del Mar. These characteristics are related to the damage statistics for the building...
Hydrodynamic Interaction Effects in Earthquake Response of Arch Dams
With the aid of earthquake response results it is demonstrated that the following hydrodynamic effects should be considered in the analysis of the earthquake response of concrete arch...
Hydrodynamic Isolation of Concrete Dams
The feasibility of reducing hydrodynamic effects in the earthquake response of concrete dams by anchoring gas-filled balloons or injecting bubbles in the water is investigated. Significant...
Seismic Evaluation of PG&E Concrete Dams
Seismic evaluation of PG&E concrete dams is an ongoing process. The seismic environment for the dams changes over time because more historical earthquake data is obtained, faults...
Earthquake Induced Cracking in Concrete Gravity Dams
An important nonlinear behavior in the earthquake response of concrete gravity dams is the formation and propagation of tensile cracks in the concrete. The earthquake response of a typical...
Seismic Design of Highrise Building with Mega Frame
The NEC corporation head office building is under construction at Shiba Minato-ku, Tokyo, Japan. This building is a highrise building of steel structure with the height of 180m. The structural...
Structural Considerations in Design and Construction Process of a 25 Story Office Building
This paper introduces an example in which a steel office building of 25 stories above the ground was constructed employing innovative techniques. One of them was the use of precast concrete...
Seismic Design of a Long-span Space Structure
This structure consists of a 5 layered complex shape of long-span steel roof structure, and reinforced concrete (RC) and steel reinforced concrete (SRC) supporting structures. The roof...
Implications for Limit State Design of Inverted V Braced Steel Structures
Inverted V braced steel structures with backup ductile moment-resisting frames forming a dual system, exhibit complex inelastic behavior under severe seismic excitations. Thus, current...
Building Frames Subjected to 2D Earthquake Motion
Inelastic response of a simplified model of a 10-storey building frame was analyzed to assess the effects of bi-directional seismic loading. Interaction between the strengths in the two...
Seismic Load Effects on a Scaled Model Structure
A long term observation on a scaled steel braced frame model with intentionally reduced seismic strength is ongoing since 1983. This paper examines the seismic load effects of two earthquakes...