Experimental Evaluation of Performance of Earthquake Restrainers in Box Girder Bridges
Type C-1 restrainers were used in most of the concrete T- and box girder bridges which have been retrofit. Type C-1 restrainers consist of 7-3/4 in. diam. galvanized cables, bearing plates,...

Vertical Response Data from the Dominion Road Bridge Test
In January and February of 1985, two bridges were tested in New Zealand using simulated earthquake loads. The objective was to determine the in-situ seismic response of two reinforced...

Bond and Dowel Action of a Main Bar in a RC Beam
The bond and dowel action are analytically treated independently on each other in most cases. The bond behavior may be, however, much affected by the dowel action in structural members....

Friction-Dampers for Economic Seismic Design
A novel structural system, which combines the strength and stiffness of a braced frame and energy dissipation capacity of the friction-dampers, has been used in the design of a reinforced...

System Identification of Meloland Road Overcrossing
The Meloland Road Overcrossing (MRO) is a two-span reinforced concrete bridge structure located east of El Centro, California, 0.3 mi from the Imperial Fault. The Imperial Valley Earthquake...

Seismic Instrumentation and Its Implication for High-Rise Buildings in Japan
An outline of the present state of the strong earthquake motions observation systems in Japan and an example of the obtained records of an earthquake and its simulation analysis of a high-rise...

Seismic Evaluation of a Tall Reinforced Concrete Frame Building
Accelerations at basement, fifth and tenth floor levels of a reinforced concrete apartment building were recorded during the October 1st, 1987 Whittier-Narrows earthquake. These accelerations...

Architectural Configurations in Vina del Mar
This paper identifies the architectural characteristics of 121 reinforced concrete buildings in Vina del Mar. These characteristics are related to the damage statistics for the building...

Hydrodynamic Interaction Effects in Earthquake Response of Arch Dams
With the aid of earthquake response results it is demonstrated that the following hydrodynamic effects should be considered in the analysis of the earthquake response of concrete arch...

Hydrodynamic Isolation of Concrete Dams
The feasibility of reducing hydrodynamic effects in the earthquake response of concrete dams by anchoring gas-filled balloons or injecting bubbles in the water is investigated. Significant...

Seismic Evaluation of PG&E Concrete Dams
Seismic evaluation of PG&E concrete dams is an ongoing process. The seismic environment for the dams changes over time because more historical earthquake data is obtained, faults...

Ductility and Failure Characteristics of Concrete and Rock Subjected to Complex Load Paths
Strength, ductility and the complex material response features of concrete and rock should be evaluated through carefully planned material properties test programs designed to subject...

Earthquake Induced Cracking in Concrete Gravity Dams
An important nonlinear behavior in the earthquake response of concrete gravity dams is the formation and propagation of tensile cracks in the concrete. The earthquake response of a typical...

Structural Considerations in Design and Construction Process of a 25 Story Office Building
This paper introduces an example in which a steel office building of 25 stories above the ground was constructed employing innovative techniques. One of them was the use of precast concrete...

Seismic Design of a Long-span Space Structure
This structure consists of a 5 layered complex shape of long-span steel roof structure, and reinforced concrete (RC) and steel reinforced concrete (SRC) supporting structures. The roof...

A Damage Model for Reinforced Concrete
The damage index developed by the authors models concrete damage as a low-cycle fatigue phenomenon. By quantifying the energy dissipated as a fraction of the total energy dissipation capacity,...

Seismic Vulnerability and Retrofitting of Buildings. Recent Experiences in Mexico City
Measures taken in Mexico City after the 1985 earthquake to evaluate the safety of existing buildings, to strengthen damaged structures and to retrofit those that were considered to need...

Seismic Vulnerability Evaluation in Japan
The state of the art in Japan is reviewed on the evaluation of the seismic capacity of existing low- to mid-rise reinforced concrete buildings, taking into account the different resistance...

Comparison of Slitted and Non-Slitted R. C. Shear Walls With Boundary Elements Under Horizontal Forces
This paper compares the differences of aseismic behaviours between slitted and non-slitted shear walls under horizontal forces. There are 5 specimens for slitted shear walls and another...

Nonlinear Analysis for the Aseismic Strength of Highrise Steel Frame With Semi-Rigid Joints by Pseudo-Elastic Approach
This paper suggests that the direct stiffness method is still useful in dealing with the nonlinear analysis for the aseismic capacity of highrise steel frame while the Pseudo-elastic approach...

 

 

 

 

Return to search