Lateral Buckling: A Comparison of AISC-LRFD and Eurocode 3
The nominal moment capacity of laterally unsupported, doubly-symmetric, steel I-beams are computed and compared using the AISC-LRFD and EC 3 design recommendations. A review of the EC...

Innovative Design of Steel Gable Frames
Common wisdom holds that conventionally designed gable frames fabricated from rolled sections cannot compete with metal building system frames fabricated from plate and bar stock, from...

Local Web Crippling of Unstiffened Multi-Cell Box Sections
Full-scale experiments and analyses show that the AISC/LRFD design equations for web yielding and web crippling strength of unstiffened webs, developed from test data on I sections, can...

Evaluation of Corroded Steel Chimneys
The paper is focused on the analysis of corroded steel chimneys. Cylindrical steel plates are exposed to thermal and chemical effects. The study is based on the results of extensive measurements...

Seismic Evaluation of the Tied-arch Bridge Across the Mississippi River on I-40
The bridge reported in this paper is a two-span steel tied-arch bridge supported on massive caisson foundations. Site specific seismic studies were carried out to establish the ground...

Seismic Study of Historic Bridges in Eastern United States
The main objective of this paper is to study the Barrackville bridge and its response in resisting static and seismic loads. Since the design was based on controlled deflections, the analyses...

SemiActive Structural Control: A Low Cost Fix for An Infrastructure at Risk
There is increasing societal pressure on the engineering profession to develop cost effective methods to extend the service life of the civil infrastructure. While the degradation of the...

Discontinuous Control of Seismic-Excited Nonlinear and Hysteretic Structures
Based on the theory of variable structure system (VSS) or sliding mode control (SMC), discontinuous control methods are presented for application to seismic-excited nonlinear civil engineering...

An Application of a Coulomb Damped Mass Device
A new, passive, dissipation device which utilizes Coulomb friction to reduce horizontal structural motions is adapted to an actual vertical vibration problem. An analysis by numerical...

Moment-Rotation Behavior of Pultruded Beam-to-Column Connections
Presented are experimental details and results of five tests carried out to study the moment-rotation behavior of flange cleated connections for frames of pultruded members. The full-sized...

Progress in Reinforced Concrete Column Design: An Introduction
The Joint ASCE-ACI Committee 441 on Reinforced Concrete Columns is investigating a number of problems related to structural behavior and design of reinforced concrete columns. This paper...

Design of Lateral Steel in Columns
Lateral steel in columns is generally required for shear resistance, confinement of concrete and prevention of buckling of longitudinal bars. This paper is limited to the design of lateral...

Rational Limits for Longitudinal Steel in Concrete Columns
Current limits for the amount of longitudinal reinforcement in concrete columns were established more than 60 years ago. Commercial grades of reinforcement in 1930 were about half as strong...

High-Strength Concrete Columns: State of the Knowledge
This paper consists of reported information divided into two general categories, performance of High-Strength Concrete (HSC) columns under concentric loads, and combined axial and bending...

Progress in Reinforced Concrete Column Design
This paper reviews some of the design procedures used for both braced and unbraced frames constructed in reinforced concrete. The discussion refers to the problems of material and geometric...

Harmonization of Reliability-Based Timber Engineering Codes and Standards
An overview of activities related to harmonization of reliability-based timber design codes and standards is presented. The overview is based on information generated through a NATO Advanced...

Use of Composite Timber-concrete Floors in Residential Buildings
Timber-concrete floors are widely used in the Gulf region for its resistance to hot and aggressive environment of the area. However, due to the fact that no shear connector is provided,...

The Canadian Approach in the Design of Wood Structures: Conversion to Limit States Design
During the early 70's, the National Building Code of Canada (NBCC) established the principle that structural design be carried out using the limit states design (LSD) method. The technical...

Evaluation of Wood Floor Vibration Design Criteria
In the United States, floors in wood buildings are designed according to strength and deflection criteria under static uniform loads. With the introduction of engineered joist products...

Strength Variability of Wood Formwork Members
Failure of concrete formwork is one of the main causes of concrete construction failures. Among the main causes of formwork failure is inadequate strength. Currently there is no published...

 

 

 

 

Return to search