Low Strain Dynamic Testing of Wood Piles Supporting an Existing Pier
This paper presents a case history where low strain dynamic testing was performed to test wood piles supporting an existing structure. Under consideration is a 183 m long wooden pier constructed...

Some Aspects of Determination of Pile Capacity by the Wave Equation
This paper presents some new observations made during correlation study of pile capacity computed by wave equation analysis with failure load from static test. In order to determine proper...

Structural Analysis of Pavements: State-of-the-Art
This paper presents the state of the art of the structural analysis of pavements, using high-speed computers. The numerical models include layered analysis and finite-element and finite-difference...

Dynamic Model for Analysis of Concrete Pavements
A new dynamic finite-element computer program, DYNA-SLAB, for the analysis of jointed concrete pavements subjected to moving transient loads is presented. The structural model for the...

Seismic Fragility Analysis of Sheahan Pumping Building
This paper presents a seismic fragility analysis of the Sheahan pumping building located in Memphis, Tennessee. In the analysis, seismic response is determined from the response spectrum...

Estimation of Structural Damping of Buildings
The full-scale data on damping ratio are collected from 77 buildings within Japan. Almost all data are obtained from vibrations with a very small amplitude such as microtremor, man-power...

Diaphragm Action of Cladding in Low-Rise Metal Buildings
An investigation of the contribution of cladding to the lateral stiffness of a metal building is presented in this paper. The diaphragm action of the cladding tends to redistribute the...

Uplift Resistance of Plywood and OSB Roof Sheathing
A test program to determine the resistance of plywood and OSB roof sheathing to uplift pressures created by wind flowing over a residential roof structure will provide valuable data to...

3-D Dynamic Analysis of the Brent-Spence Through-Truss Bridge
A three dimensional finite element model is developed for the free vibration analysis of main bridge. The model was calibrated by comparing the free vibration analysis results with ambient...

Condition Assessment of Highway Bridges
An application of modal testing and structural identification in the condition assessment of bridges is presented. Damage definition and conceptualization is discussed. Damage detection...

Recent Studies of the Behaviour of Semi-Rigid Composite Connections
Following renewed interest in the semi-rigid properties of joints in steel frame structures, a more recently identified area of research has been the study of composite connections. The...

Design Implications of Advanced Analysis in LRFD
This paper discusses two advanced analysis methods, and their use in LRFD format. The first approach is called the notional load plastic hinge method and the second is called the second-order...

Towards Robust, Effective and Efficient Second Order Analysis of Practical Steel Frames
The performance of the widely used finite element and the stability function methods and the recently developed pointwise equilibrating element in second order nonlinear analysis of framed...

A Nonlinear-Analysis-Based Procedure for Evaluating Load-Carrying Capacity of In-Plane Steel Frames
A simple method based on geometrically nonlinear analysis is proposed to evaluate the load-carrying capacity of a steel structure. The effects of material nonlinearity and residual stress...

Behavior of Tall Frame Combining Rigid and Semi-Rigid Connections
In this paper, the applicability of the mixed use of rigid and semi-rigid connections in the tall frame is discussed. It is tried. for 4-bay 8-storey frame to be numerically analyzed for...

Seismic Analysis of Failure and Loss of Function of Water Pumping Facilities
Water company managers evaluating potential seismic damage effects on a pumping facility will require a reasonable estimate of the probable magnitude earthquake that has potential to disrupt...

Response Study of a Flexible Building Using Three Earthquake Records
This paper examines the response of a flexible building during three earthquakes. The records from the building are long and contain low frequencies. The site frequency (0.33-0.38 Hz)...

Bulb-T and Glulam-FRP Beams for Timber Bridges
In this paper, we discusses the manufacturing, analysis, and testing of two glulam beam designers:(1) Southern pine bulb, and (2) yellow-poplar reinforced with pultruded fiber-reinforced...

When are Loads Taught? A Case Study and National Trends.
Several years ago, structures faculty of the Department of Civil and Architectural Engineering at the University of Wyoming revised their structures courses to meet several new educational...

Teaching Structural Loading: A Case Study
CVEG 4803: Structural Loading course was formulated three years ago as an undergraduate senior elective course. In this course structural dynamics is introduced for one third of the course....

 

 

 

 