Seismic Analysis of Failure and Loss of Function of Water Pumping Facilities

by M. A. Cassaro, Univ of Louisville, Louisville, United States,
S. E. Hamburg, Univ of Louisville, Louisville, United States,
D. An, Univ of Louisville, Louisville, United States,
M. J. Cassaro, Univ of Louisville, Louisville, United States,



Document Type: Proceeding Paper

Part of: Structures Congress XII

Abstract:

Water company managers evaluating potential seismic damage effects on a pumping facility will require a reasonable estimate of the probable magnitude earthquake that has potential to disrupt serviceability. The analysis would determine expected force levels resulting from the interacting structures and failure analysis of the pipe structure. These analyses are presented in this report to provide an estimate of potential damage and loss of function of a pumping facility.



Subject Headings: Failure analysis | Structural analysis | Seismic tests | Seismic effects | Pumping stations | Pumps | Earthquakes

Services: Buy this book/Buy this article

 