Pseudo-Dynamic Testing of Structural Components
The pseudo-dynamic testing procedure is a simultaneous simulation and control process in which inertia and damping properties are simulated and flexibility properties are acquired from...

Seismic Tests of Friction Damped Steel Frames
This paper presents the results obtained from qualification tests of a new friction damping system, which has been proposed in order to improve the response of Moment Resisting Frames...

Nonlinear Behavior of Precast Concrete Shear Walls under Simulated Earthquake Loading
This paper presents experimental and analytical results on precast concrete shear walls under earthquake loading. It was observed in both small scale models tested and the computer analysis...

Hysteretic Behavior of Composite Diaphragms
Floor systems constructed with steel-deck-reinforced concrete are described. When used to resist lateral loads these systems are referred to as diaphragms. A description of a test arrangement,...

Precast Roofs for Blast Shelters
A shallow-buried reinforced concrete blast shelter has been constructed and dynamically tested at the U. S. Army Engineer Waterways Experiment Station (WES). Three thicknesses of precast...

Floating Bridges in Short-Crested Random Seas
Four large concrete floating bridges located in Washington State have been the subject of extensive analytical modeling for dynamic response to storm waves. The dynamic analysis of the...

Cyclic Energy Absorption by Reinforced Concrete
Results are presented on the basis of experiments conducted on conventional and steel fibrous reinforced concrete beams. The effects of the amount and nature of steel reinforcement and...

Significance of Nonlinear Modeling of R/C Columns to Seismic Response
Columns in reinforced concrete (R/C) structures exhibit complex hysteretic behavior during earthquakes. This can significantly influence predictions of overall response and damage distribution....

Building Records from 1984 Morgan Hill Earthquake
The dynamic response of 23 structures instrumented by the California Strong Motion Instrumentation Program was recorded during the magnitude 6. 2 (ML) Morgan Hill earthquake of 24 April...

Use of Vibration Tests to Determine Lateral Load Paths in Medium Rise Buildings
A structural system identification procedure is described in which an initial analytical model of a building is modified until it predicts accurately the mode shapes and natural frequencies...

Behaviour of Full-Scale Reinforced Concrete Structure on Realistic Foundation
A full-scale seven-story reinforced concrete building, tested as a part of U. S. -Japan Cooperative Research Program, performed well even under a severe earthquake loading condition. Nonlinear...

Modeling 3-D Response in R/C Frame-Wall Structures
As part of the recent U. S. -Japan Cooperative Research Program on the seismic performance of buildings, a 1/5-scale model of a 7-story reinforced concrete frame-wall structure, was constructed...

Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part I Gross Behavior
As a part of the U. S. -Japan Cooperative Research Program Utilizing Large-Scale Testing Facilities, a six-story, 2 by 2 bay, concentrically K-braced steel building was constructed in...

Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part II Local Behavior
The full-scale six-story concentrically K-braced steel building was subjected to Miyagi-Ken-Oki simulated earthquake whose peak intensity was 500gal. Local behavior of the test building...

Slab Participation in Frames under Lateral Loads
A unique opportunity to study slab participation was afforded by the U. S. -Japan Cooperative project on large scale testing. The data obtained from the full-scale 7-story building tested...

Earthquake Response Simulation Capacity of Pseudo Dynamic Testing?Experimntal Demonstration and Analytic Evaluation
The response accuracy of the pseudo dynamic test was evaluated from the shake table and pseudo dynamic tests conducted for a two story steel braced frame model. The obtained responses...

Earthquake Response of Five Story Reinforced Concrete Masonry Test Building
In 1986, a full-scale five story reinforced masonry test building is to be constructed in the Japan Building Research Institute Large-Scale Structure Test Laboratory, and through 1987...

Flexural Behavior of Reinforced Masonry Walls and Beams
Many reinforced masonry walls and beams were tested as a part of the U. S. -Japan cooperative research program on masonry building structures. Six concrete block and two clay brick masonry...

Full Scale Tests of Cladding Components
A full scale, six story, steel frame at the Building Research Institute, Tsukuba, Japan was constructed for a series of projects in the U. S. -Japan Cooperative Research Program. This...

Stiffness Parameters Identification of Frames
Four widely used methods of structural system identification are presented. A new formula and its derivation, based on the Bayesian estimation theory, is given. Time domain responses of...

 

 

 

 

Return to search