Earthquake Response Simulation Capacity of Pseudo Dynamic Testing?Experimntal Demonstration and Analytic Evaluation
by Yutaka Yamazaki, Ministry of Construction, Tsukuba, Japan, Ministry of Construction, Tsukuba, Japan,Masayoshi Nakashima, Ministry of Construction, Tsukuba, Japan, Ministry of Construction, Tsukuba, Japan,
Takashi Kaminosono, Ministry of Construction, Tsukuba, Japan, Ministry of Construction, Tsukuba, Japan,
Document Type: Proceeding Paper
Part of: Dynamic Response of Structures
Abstract:
The response accuracy of the pseudo dynamic test was evaluated from the shake table and pseudo dynamic tests conducted for a two story steel braced frame model. The obtained responses were compared, and their correlation was estimated. It was found from the comparison as well as post numerical analysis that the accuracy of the pseudo dynamic response is very satisfactory.
Subject Headings: Shake table tests | Dynamic tests | Steel frames | Model accuracy | Earthquakes | Dynamic structural analysis | Simulation models