The Foundation for a New Approach to Implement Building Innovation
Prepared by the Partnership for Building Innovation project, which is sponsored by CERF; National Institute of Standards and Technology; U.S. Department of Housing and Urban Development;...
Inelastic Response of Metal Matrix Composite Tubes
An analytical method which exactly satisfies the equations of the boundary value problem for the inelastic response of laminated metal matrix composite tubes on a point-wise basis is presented....
The Inelastic Response of an Offshore Platform in Hurricane Andrew
Amoco's Gulf of Mexico South Timbalier 161A platform took a direct hit from Hurricane Andrew in August of 1992, experiencing loads which far exceeded its design load. The platform had...
Design of Mat Foundation for Egg Shape Digesters
Two levels of ground motion, the Maximum Probable Earthquake and the Maximum Credible Earthquake, were considered in designing the 2.5 million gallon egg shape digesters and their combined...
Coupling Translation and Rocking Motions
In the design of concrete block foundations for rotating and reciprocating machines, it is important to avoid resonant conditions. Therefore, accurate determination of the frequencies...
Case Study - Performance of Diaphragm Walls During Construction; Predictions vs. Field Measurements
Rigid diaphragm walls (slurry walls) are being used more than any other earth supporting system for underground construction projects in confined downtown sites throughout the United States...
Seismic Evaluation of the Tied-arch Bridge Across the Mississippi River on I-40
The bridge reported in this paper is a two-span steel tied-arch bridge supported on massive caisson foundations. Site specific seismic studies were carried out to establish the ground...
Effects of Site Conditions of Earthquake-Resistant Design of Structures
After a brief discussion of the importance of reliable establishment of design Earthquake Ground Motions (EQGMs) for efficient Earthquake-Resistant Design (EQ-RD) of structures, this paper...
Site Effects on Strong Shaking and Seismic Risk: Recent Developments and Their Impact on Seismic Design Codes and Practice
The very strong influence of localized poor or 'adverse' geological/geotechnical foundation conditions on patterns and concentrations of damage during a number of recent earthquakes (e.g.:...
Guide for the Design of Prestressed Concrete Poles
With the aim of providing engineers with some basic tools and guidelines for the design of structures, the committee prepares code and policy changes, and to expand input of manufacturers...
Overview - Electrical Substation Structures Design Guide
The ASCE Substation Structures subcommittee of the Committee on Electrical Transmission Structures (CETS) is developing a substation structures design guide. The guide discusses the analysis...
A Self-Balancing Laminate
A self balancing wood laminate has been developed based on the principle of orthotropic elasticity. Lumber is cut into three sections in the flatwise plane and each side member is turned...
Creep Analysis of Composite Steel-Concrete Members with Deformable Connectors
The long-term analysis of composite steel-concrete beams with elastically deformable connectors is presented. The basic integro-differential equation governing the problem is solved by...
SDC Detector Foundation Requirements for the SSC
The Solenoidal Detector Collaboration (SDC) detector weighs approximately 32,000 metric tons, and its ability to perform to design specifications is directly related to its internal alignment....
High-Strain Kinetic Testing of Deep Foundations
High-strain kinetic testing involves the upward decelerating or accelerating of a mass and using its inertial force to axial prolonged pulse at the head of a pile. Currently available...
Interpretation of Nondestructive Integrity Tests Using Artificial Neural Networks
A barrier to more frequent use of nondestructive integrity tests on cast-in-place foundations is the difficulty of interpreting the test results to identify the presence or absence of...
Messeturm Tower: Frankfurt, Germany
A 256 meter (840 feet)tall office tower, currently the tallest building in Europe, has been constructed in Frankfurt Germany. The 7- story structure with 85500 square meter (920,000 square...
The Structural History of the Jacob Bachmann Tavern
The Jacob Bachmann Tavern is located in Easton, Pennsylvania. It is a collection of four interconnected buildings that have been constructed and modified over a period of 240 years. Structural...
Discrete Field Stability Analysis of X-Braced Lattices
The three-dimensional X-braced lattice is used as a compression member in structures ranging from the long span roof of buildings to radio and television antennas. In such cases the design...
Nonlinear Buckling Response of Single Layer Latticed Barrel Vaults
Elastic overall buckling of single layer latticed barrel vault roof structures under static vertical loading is investigated using a fully nonlinear finite element solution procedure and...