Design of Guideway Substructure Dada County METROMOVER
This paper describes the procedures and parameters used for the design of the guideway substructure for the Dade County METROMOVER system. The substructure for this work is defined to...
Summary Evaluation of Dade County's APM Foundations
This paper presents an overview of the engineering performance and cost effectiveness of the guideway and station foundations of Dade County's Automated People Mover (APM)....
Unique Considerations in the Detroit DPM Foundation Design
Foundation design for the guideway of Detroit's Downtown People Mover (DPM) was influenced by a variety of unique considerations. Severe loading conditions were created by...
Centrifuge Model Testing with Dynamic and Cyclic Loads
This paper examines the use of small-scale tests on centrifuges to study a wide range of problems in soil dynamics - including machine foundations, structures and explosion effects. The...
Uplift Behavior of Shallow Soil Anchors?An Overview
An overview is presented of the static uplift (tensile) behavior of shallow anchors used for foundations in soil. Basic anchor types are described, and their general installation and behavioral...
Uplift Capacity of Shallow Offshore Foundations
Soil failure under upward loading is investigated by experimental laboratory tests. The problem of uplift capacity is considered in terms of effective stresses in soil skeleton and pore...
Transmission Tower Foundations in Weathered Rock
A case history is presented which discusses the siting, design and construction of the tower foundations for a transmission line in southwest Alaska. The project, completed in 1983, consists...
New Exchequer Dam, California
New Exchequer Dam design, in 1963, was in the transition period in which dumped rockfill was being recognized as having undesirable settlement characteristics, and compaction of rockfill...
Weak Rock in Two Rockfill Dams
Two South Australian concrete face compacted rockfill dams, built from soft rock won from each dam site, have performed successfully in service with only small leakage and settlements...
Design and Performance of Shiroro Rockfill Dam
Shiroro Dam, constructed across the Kaduna River in Nigeria, is a rockfill dam with reinforced concrete facing. The dam was completed in late 1983, and reservoir impounding started in...
Design Features of Salvajina Dam
Salvajina dam is the second highest concrete face rockfill dam currently in service in the world. The characteristics of the foundation of the toe slab vary from fresh, sound and little...
Construction and Performance of Salvajina Dam
Salvajina Dam was constructed between July, 1982 and November, 1984. Relevant construction aspects are described, particularly those related with procedures and statistical data of the...
Khao Laem?A Concrete Face Rockfill Dam on Karst
A continuously reinforced concrete faced rockfill dam has been successfully designed and constructed on a karstic limestone foundation in Central West Thailand. The dam is not in an earthquake...
Kotmale Dam and Observations on CFRD
A concrete faced rockfill dam was the type selected for the 300 ft (90 m) dam at Kotmale in Sri Lanka for reasons of economy and speed in construction. Standard design concepts were tailored...
Design of Concrete-Faced Rockfill Dams
Design principles adopted in 1966 by the Hydro-Electric Commission have been applied to nine concrete-faced rockfill dams and remain substantially unchanged. Experience shows that the...
Design of Deer Creek Dam
The Deer Creek Dam is proposed to be a concrete face rockfill structure (CFRD) with upstream and downstream slopes nominally 1. 3 horizontal to 1 vertical. The embankment will rise 280...
Machadinho Dam in Brazil
This paper presents the reasons for selection of a concrete-face rockfill dam for Machadinho Hydroelectric Project in Brazil. It also describes the main characteristics of the dam, as...
The Design of Macagua Concrete Face Rockfill Dam
This article describes the design characteristics of the concrete face rockfill dam at Macagua, which will have a total length of about 9,200 ft (2,800 m), an average height of 66 ft (20,0...
Foundation Design Considerations for Detroit DPM
The design loadings for support of the elevated guideway of the Detroit Downtown People Mover (DPM) consist of high vertical as well as horizontal loads. In order to simplify foundation...
Design of Cirata Concrete Face Rockfill Dam
The Cirata Hydro-Electric Project on the Citarum River in Western Java, Indonesia is at present under construction for Perusahaan Umum Listrik Negara (PLN). The project which is being...
Return to search