Full-Scale Automation of an SBR Wastewater Treatment Facility
Due to advantages offered by discontinuous wastewater processing, considerable attention has been given to the use of sequencing batch reactor (SBR). This paper will examine the implementation...
Removal of Trace Organics in MunicipalWastewater
This paper presents the results of three years of monitoring effluent quality from two treatment facilities for trace organic chemicals in Pima County, Arizona. Approximately thirty 24-hour...
Evaluation of Chlorine Dioxide and Ozone Preoxidation on Conventional Treatment and Direct Filtration
The renewed interest in the use of chlorine dioxide and ozone as preoxidants has focused mainly on their effectiveness on color and THM precursor removal and as disinfectants. This paper...
Experimental Verification of a Unified Chlorine-Ammonia Reaction Model
A model of the reacting aqueous chlorine-ammonia system is proposed which describes equally well the rapid 'breakpoint' oxidation of ammonia or the slow decomposition...
Slow Rate Sand Filtration Using a Zeolite Surface Amendment
The objective of the study was to obtain detailed information regarding amended filter performance at surface loading rates 2 to 4 times higher than standard flow rates. Experiments were...
Meeting Revised Drinking Water Regulations Using Conventional Treatment Methods
This paper discusses the removal efficiency of standard treatment processes for each of the four groups of contaminants. The evaluation of a process's capability to meet the...
Removal of Radon and Uranium from a water supply
The removal of Radon and Radium from drinking water with the help of granulated activated carbon (GAC) adsorption was investigated. A packed bed column was used for the purpose. It has...
Low Head Filtration Removal Efficiencies of
The removal of Giardia cysts from low turbidity waters is of great concern in many areas of the United States. A pilot program was undertaken to determine if an established low head filtration...
Application of a Relative Site Ranking Methodology to Regulation of Groundwater Contamination Sites
An assessment methodology for ranking groundwater contamination sites is described. The ranking of nearly 100 actual contamination sites, and the definition and calibration of 'zones...
Remedial Measures for a Creosote Impoundment Closure
In conformance with the 1984 amendments to the Resource Conservation and Recovery Act (RCRA) Part 264 requirements, Burlington Northern Railroad (BN) constructed a double high density...
Biological Removal of Low Levels of Chlordane
This study investigated the removal of chlordane from a synthetic hazardous waste landfill leachate with chlordane as the only hazardous material. The chlordane concentrations investigated...
Effect of Wastewater Characteristics on the Sulfide Problem (
This paper presents an overview of various wastewater characteristics with which the designer should be familiar, and the effect of those characteristics on the sulfide problem, including...
Land Disposal Construction, Monitoring and Closure
The continuous generation of hundreds of thousands of gallons of hazardous wastewater and waste process solutions each year at an aerospace development and assembly plant at Lockheed Missiles...
Risk Assessment Methodology for Determining Groundwater Contamination from Landfilling Sludge
Contaminant concentration criteria are required to prevent contaminant infiltration from leading to conditions which exceed health criteria. A methodology of groundwater has been described...
Models of Organics Transport Through Soil Columns
A mathematical model is proposed for the transfer of organic solutes in soil. Two cases are considered namely transport of non-adsorptive solutes and transport of adsorptive solutes. Comparative-study...
Modeling Dispersion in Non-Homogenous Formations
A stochastic model of contaminant mixing in non-homogeneous porous media has been developed. The model is three dimensional and relates the contaminant distribution to the probability...
Data from Most Monitoring Wells in Limestone Terranes Are Irrelevant to Pollutant Detection but Reliable Monitoring Can Be Attained: Why and How
The conventional system of using three or more monitoring wells placed down-gradient from a site and one or more background wells placed up-gradient from it is extremely unlikely to detect...
Effects of Sampling Equipmenton the Chemical Integrity of Groundwater Samples
Proper sampling of groundwater is one of the basic steps in monitoring movement of pollutants in groundwater systems. The effect of the use of silicone rubber when used as a bladder in...
Sulfide Control in Omaha and Cedar Rapids
Omaha, Nebraska, and Cedar Rapids, Iowa have been involved in efforts to control sulfide in major interceptors, at the influent to the treatment plants, and within the treatment facilities....
Effect of Particle Size on Sludge Dewaterability
Using a modified Buchner funnel apparatus to measure specific resistance and a sequential centrifugation/filtration procedure to fractionate a sludge, it was possible to more precisely...
Return to search