Application of Field Proven Fine Bubble Membrane Aeration Technology
Fine bubble membrane diffusers represent a significant technological advancement in diffused aeration technology by providing the consistently high transfer efficiencies of fine bubble...
Importance of Aeration Basin Detention Time in the Activated Sludge Process
Aeration basin detention time is a key design parameter for an activated sludge system at a wastewater treatment plant. The impacts of reducing the aeration time is illustrated by a case...
Control of
The paper reports on a study to determine the cause(s) of the biological imbalance and identify corrective measures. Project activities included: isolation and identification of filamentous...
Optimizing the Activated Sludge Process by Encouraging Futile Cycling
A study was conducted to demonstrate that cell yield in activated sludge processes can be decreased without increasing oxygen consumption by applying operating conditions that encourage...
Incremental Risk Analysis in Teaching Institutions
Institutions engaged in research and teaching in the natural sciences, constitute a diffuse source of chemical emissions. As many institutions embark on ambitious building programs, communities...
Risk of Waterborne Infectious Illness Associated with Diving in the Point Loma Kelp Beds, San Diego, CA
There is considerable interest in estimating the risk of bacterial and viral illness (i.e., disease, infection) associated with scuba diving in the Point Loma kelp beds located within...
Environmental Risk Assessment at a Gas Utility
Over the past 10 years, Southern California Gas Company (SoCalGas) has developed an environmental risk management program to mitigate or eliminate the potential health risks to employees,...
Monte Carlo Simulations of Uncertainties in Risk Assessments of Superfund Sites Using Crystal Ball?
Most health risk assessments for Superfund sites combine a series of worst case assumptions to derive a 'point estimate' of risk that is 'conservative,'...
Expert Systems for Assessment of Radon Gas
This paper covers a brief discussion of enviro-geotechnical aspects of radioactive toxic radon gas. Basic information required for assessment and controlling this gas is summarized and...
Occupational and Environmental Exposures to Radon: A Perspective for Mitigators
Occupational exposures to radon and radon decay products and the associated high incidence of radiation induced lung cancer form the basis for our present-day concern for limiting exposures...
Radon Entry & Control Versus Indoor Dynamics
The measurements of air infiltration, interzonal transport and exfiltration as the diagnostic procedures have been significantly influential in the selection, implementation and evaluation...
Gamma Exposure from Rn Progeny in GAC Units
An investigation into the gamma exposure rate generated by granular activated carbon (GAC) water treatment units focused on ten sites that covered a range of source radon (Rn) in water...
Technical Issues Related to Emission Releases from Subslab Radon Mitigation Systems
Surveys of government and private sector radon mitigation activities indicate that subslab radon mitigation systems account for more than 50 percent of all installed systems. Such systems...
Ozonation of a Biorefractory Organic Compound
This study involved determination of the degradation of chlorendic acid due to ozonation, possible biodegradation of the resultant products, and possible toxicity of the resultant products....
Hazardous Waste Disposal: An Attitudinal Affront
Modern disposal facilities are thorough and conscientious in their methods. Environmentally sound practices are essential to protect the company and its clients from liability. The average...
Using Borosilicate Glass as a HLW Storage Medium
There is growing concern over the quality of present high level waste management techniques. Instances of nuclear accidents and contamination at nuclear waste sites in the United States...
Challenges Posed by Large-Scale Asbestos Abatement Projects in Occupied High-Rise Buildings
The challenges posed by a large-scale asbestos abatement project are great: providing a safe indoor environment for building tenants and property that is liability-free for the building...
Conducting a Waterline Corrosion Evaluation
A study has been conducted to determine the level of corrosion activity occuring on the U.S. Navy's potable waterlines on Guam. The study evaluated soil parameters including...
Loss of Carrying Capacity in Pipes?Transporting Softened Water with High pH
The increase in pipe roughness and loss in carrying capacity for water mains carrying high pH water is documented with over 20 field tests conducted in Austin, Texas. The data show that...
Pre-Treatment Process Control of a Variable Quality Raw Water Supply
The West Coast Regional Water Supply Authority is the public agency charged with the development of public water supply for the Tampa Bay Area in the state of Florida. The Authority's...