Dynamic Consolidation Test on Soft Coastal Sediments
This paper documents an investigation of foundation improvement by dynamic consolidation for a coastal power plant site in the southern Red Sea. The investigation comprised a field test,...
Determining Sand Strength by Cone Penetrometer
Evaluation has been made of several theories and methods for deducing sand strength from cone resistance. Bearing capacity theories, cavity expansion theory, and empirical methods have...
Site Characterization Using the Cone Penetrometer Test
The Cone Penetrometer Test (CPT) when used in conjunction with a limited soil boring program can provide a more detailed and economical site characterization. This paper addresses how...
In-Situ Testing to Characterize Electric Transmission Line Routes
A review of the literature has shown few definitive studies which separate test variability from soil inhomogeneity. A sensitivity study was performed to evaluate the effects of the overall...
In Situ Testing of Calcareous Sand?Campos Basin
Sampling and in situ testing were used to investigate soil conditions for the installation of offshore platforms at the Campos Basin, Brazil. At these sites calcareous sand formations...
Soil Improvement Evaluation by CPT for Tanks
Trial soil improvement by gravel compaction piles and dynamic consolidation, and a subsequent full-scale loading test on loose volcanic ash soil were conducted prior to the design of large...
High Quality Sampling and In Situ Testing for Deep Water Geotechnical Site Investigation
This paper discusses methods that have been used to conduct geotechnical investigations in water depths up to 2500 feet. Investigations can be conducted from supply boats, geotechnical...
Effect of Cementation on the Cone Penetration Resistance of Sand
A laboratory study was conducted to investigate the effect of cementation on the cone penetration resistance of sand. A new apparatus to form homogeneous artificially cemented sand specimens...
Design Parameters for Grouted Piles in Rock From In-Situ Load Tests
A series of pile load tests were performed at an onshore site to develop final geotechnical parameters for the Gaviota platform foundation which consists of large diameter drilled and...
CPT/DMT QC of Ground Modification at a Power Plant
The use of 908 static cone penetration test (CPT) and 33 Marchetti dilatometer test (DMT) soundings provided the quality control (QC) needed to improve a power plant site by the use of...
Rehabilitation of Blackfoot Dam In-Situ Testing and Analysis
The dam was constructed in 1909 and was recently found to require rehabilitation to enlarge the spillway and improve embankment stability against the large earthquake potential in the...
Bearing Capacity of Footings on Clay CPT Method
A method is proposed to predict the ultimate bearing pressure for footings on clay using data from cone penetration tests. This method relates the ratio of ultimate soil bearing for a...
In Situ Measurement of Permeability in Soft Clays
As part of an extensive field programme, the magnitude of errors due to clay remoulding and filter clogging in tests performed in common piezometers is evidenced. Comparisons between variable...
Skin Friction Evaluated From Friction Meter Test
This paper first describes the features of a specially developed friction meter and its operation method, and then reports in-situ test results conducted on various types of soils at two...
Uplist Capacity of Pile Foundations Using CPT Data
Southern California Edison Company has performed field uplift load tests on concrete driven piles, cast-in-place straight shaft piles and cast-in-place belled piers along transmission...
The Mudslide Profile Method to Measure the Undrained Shear Strength of Muds
Mudslides have been reported to have a very distinctive profile. Using this distinctive profile, a method is presented to analyze the stability of the mudslide at limit equilibrium conditions....
Vane Shear Testing for Staged Construction
Staged construction was used for the earthfill embankment of Birch Dam in order to compensate for low strength clays in the foundation. Sampling and testing of foundation soils verified...
Interpretation of CPT Data for Design of Earth Dams Near Tehachapi, California
The Static Cone Penetration Test (CPT) was used to obtain needed geotechnical information for design and construction of two small earth dams near Tehachapi, California. The basic CPT...
Seepage Studies Using Tracers and the Self Potential Test
Mill Creek Dam, a homogeneous silt structure resting on a conglomerate foundation, has experienced severe 'seepage since its construction in 1941. In 1981, a concrete cutoff...
Analysis of Liquefaction Potential by Insitu Testing
This paper describes the results of insitu testing performed to assess the liquefaction potential of a sand formation at a site for a proposed large industrial facility in East Central...
Return to search