On the Critical Relative Displacement of Pile Shaft and Surrounding Soil
Model pile pull-out tests have been conducted to investigate the characteristics of the critical relative displacement at which the critical pile skin resistance is mobilized. Test results...
CUFAD: A Computer Program for
A research effort within the electric utility industry has focused on unified design methods for axially loaded foundations for transmission line structures. This research has been made...
Foundation Studied for Turbine-Generator on Liquefiable Soils
Turbine-generator foundations are generally constructed of concrete in the U.S.A. This paper deals with the dimensioning and evaluation of a turbine foundation in Oxnard, California. The...
Ground Failure Damage to Buildings During Earthquakes
Several case histories are examined to evaluate building damage as a function of the foundation type and type and amount of ground displacement. Extensional or vertical ground displacements...
Effect of Site Soil Properties on Seismic SSI Response of Embedded Structures
In a series of two-dimensional soil-structure interaction (SSI) analyses, seismic responses, including the SSI effect of a deeply embedded reactor building of a standard plant in different...
Seismic Response Study of Two Memphis Sites
This paper presents a study to evaluate the soil effects on earthquake ground motion of two selected sites in the Memphis area. Twenty artificial bedrock acceleration time histories with...
Simplified Seismic Analysis of Pile Foundations
The determination of displacement of the pile cap and displacements and forces of individual piles is essential to the design of pile foundation subject to both static and/or dynamic loading....
Seismic Response Considerations in Foundation Design
There are no generally accepted procedures to determine the potential magnitude of reduction of footing bearing capacity that may result from soil strains or pore pressure changes during...
Risk Correction Factors for Bearing Capacity Analysis
In this paper bearing capacity correction factors are developed to account for the randomness in the load and soil properties. These are applied to the bearing capacity equation in the...
Movement Control of Excavation Support Systems by Iterative Design
Conventional design practice for excavation support systems emphasizes determination of loads and selection of structural components. This paper presents a method which uses movement control...
Some Expert System Applications in Geotechnical Engineering
Knowledge-based expert systems (KBES) represent a new technology for computer-aided engineering. These systems can be useful in situations which involve expert judgments for effective...
Geotechnical Judgment in Foundation Design
This paper summarizes the initial findings of a research project to investigate the judgment-making process of foundation engineers. Solutions for a typical design problem were solicited...
Structural Foundation Practices for Highway Projects
The state-of-practice by State transportation agencies, in the area of structural foundations, is compared between the late 1970's and the present. The structural foundation...
Bearing Pressure?SPT Correlations for Expanded Base Piles in Sand
Design of enlarged base piles is usually carried out using correlations between SPT N values and point resistance. The results of full scale load tests are used to show that base resistance...
Owner and Designer Advantages Derived from Use of Construction Consultant
There are two significant ways that an experienced construction consultant can assist both the owner and the designer/engineer in obtaining an economical and practical structure. Constructibility...
Some Observations on Undrained Side Resistance of Drilled Shafts
A data base of 106 field load tests (65 in uplift and 41 in compression) is used to evaluate the undrained side resistance of drilled shaft foundations. The total stress or alpha (?) method...
Nondestructive Testing of Deep Foundations with Sonic Methods
Nondestructive testing and evaluation (NDT&E) of deep foundations with three sonic methods is discussed. Case history investigations described include test records from drilled...
Geophysical and Nuclear Methods for Non-Destructive Evaluation of Caissons
Non-destructive testing techniques were used to confirm the concrete integrity on the caisson foundations for the 45-story Ohio Corporate Headquarters building in Cleveland, Ohio. The...
Pile-Drilled Caisson Combination for Foundation of High Rise Building
The analysis and evaluation of several alternatives for foundations of a high rise office building is presented, which resulted in the selection of a combination of high capacity piles...
Combination Drilled Shaft and Driven Pile Foundation for a High-Rise Building
A case history is presented which discusses the design and construction of a combination drilled shaft and driven pile foundation which supports a high-rise in San Francisco. Drilled piers,...
Return to search