Field Burial Tests of Corrugated Double Wall PVC Pipe
A new lightweight PVC pipe, consisting of a smooth inner wall and a corrugated outer wall, has been introduced in the U. S. sanitary sewer market in 4 through 10 in. diameters. Field burial...
Long Term Deflection of Buried Plastic Sewer Pipes
During the 70's and the early 80's a research program has been carried out in Sweden regarding the long term behaviour of buried plastic pipes. The program has...
Determining the In-Place Density of Soils Using the Sleeve Method
The sleeve method of determining the in-place density was developed by Bureau of Reclamation field personnel for cohesionless, fine, gravel soils used for pipe bedding when other methods...
Buried Fiberglass Pipe Response to Field Installation Methods
In 1970 near Yuma, Arizona, a field test installation of 30 inch diameter fiberglass pipe was constructed. Twelve years later the pipeline was remeasured. Measurements of pipe profile,...
Long Term Testing of Centrifugally Cast Glass Fibre Reinforced Plastic Pipes (RIRP)
The paper discusses testing of pipe manufactured by centrifugal molding. The tests included external load tests, internal load, hydrostatic internal pressure, and cyclic internal pressure....
A Study of Inlet Control Alternatives for SWM
A laboratory study of alternatives for effecting inlet control on urban storm sewer systems for stormwater management (SWM) is described. The test facility was a full-size physical model...
Field Testing of 84-Inch-Diameter Plastic Pipe
During the summer of 1981, a research project was initiated to monitor strains and deformation in 84-inch diameter RPM (reinforced plastic mortar) pressure pipe. Three 20-foot (6. 1-m)...
Successful Use of Centrifugally Cast Glassfiber Reinforced Plastic (GRP) Pressure Pipes for Public Works in Sweden
Centrifugally cast GRP pipes were introduced in Sweden 17 years ago for industrial applications mainly as a gravity pipe. The process of pipe manufacturing as well as the pipe itself and...
Influence of Frost Action on the Load Exerted on Buried Pipe
When work was started on revising the Swedish code for concrete pipes at the end of the 70's, a research project was carried out to evaluate the risk of increased load due...
Designing for Residual Flooding
Flood control projects should incorporate designs and responses for flooding of the protected areas due to exceedance, overtopping, or failure of the features. Design strategies for levees,...
Aggregation and Consolidation of Phosphatic Clays
The consolidation behavior of aggregated phosphatic clays has been investigated using a bench scale centrifuge. It was determined that aggregation of the clays with phosphogypsum, a waste...
A General Microcomputer Approach for Evaluating Ground-Water Responses
A general impulse response function for calculating responses for stream-aquifer interaction, pumping in leaky and nonleaky artesian aquifers, and two dimensional dispersion is presented....
Reliability Evaluation of Water Distribution System Components
Reliability engineering concepts are substantially developed and have been routinely and successfully applied to the evaluation of electrical and mechanical components. However, these...
Integration of Micro, Mini, and Mainframe Computers in WES Hydraulics Studies
The U. S. Army Corps of Engineers Waterways Experiment Station (WESA) Hydraulics Laboratory is involved in hydraulic studies of navigation and flood control projects of the Army Corps...
Application of Water Budget to Seepage Loss Estimation
The seepage loss for the emergency cooling water spray pond has been calculated by performing a water balance study for the pond. A field test of the spray pond was performed to estimate...
A Ground Water Flow Model for Protection of the Northwest Well Field, Dade County, Florida
A new study was initiated to determine the appropriate cone of depression for the Northwest Well Field and to develop land use restrictions within that area. A finite-difference ground...
Field Evaluation of a Diffuser-Induced Mixing Model
Early physical model studies of the diffusers at Browns Ferry Nuclear Plant qualitatively document the mixing characteristics of the thermal effluent. Based on these studies, the dilution...
Integrated Hydrothermodynamic Study of Browns Ferry Nuclear Plant
The results of hydrothermodynamic analyses and computer models discussed in previous papers are combined to present an integrated study supporting a request for alternative thermal limits...
Interactive Computer Aided Graphic Water Well Pumping Test Evaluation Software
A microcomputer software package was developed which allows the user to interactively evaluate pumping tests using semilog and log-log graphic methods for time-drawdown, step-drawdown,...
Using Microcomputers for Groundwater Flow Analysis
Micro-computers offer an effective and efficient method for rapid and comprehensive analyses of groundwater flow. There are now numerous codes which have been developed specifically for...
Return to search