Improved Design Procedure for Shallow-Buried Structures to Resist Airblast Loading
Both conventional and nuclear weapons generate airblast loads of sufficient magnitude that structure survival at acceptable cost favors below grade construction. The design of shallow-buried...
Drop Test of Dolos Armor Units
Dolosse are concrete armor units used for the cover layer on many breakwaters and jetties. In order to study their complex loads and structural response, a prototype study at Crescent...
Anchorage Forces for Z-Purlin Supported Standing Seam Roof Systems
This paper presents the results of a limited study to determine if the provisions of Section D. 3. 2. 1 'Anchorage Bracing for Roof Systems Under Load with Top Flange Connected...
Bending Strength of Thin Cold-Formed Steel Straight Panels
An experimental investigation on the bending strength of 26 gage cold-formed corrugated steel straight panels with web-depth to thickness (h/t) ratio of 475 is presented. A typical test...
Behavior and Design of Semi-Rigid Composite Frames
Recent advances and experimental research on the behavior of composite semi-rigid frames indicates that substantial savings can be achieved with this method of construction. The current...
Centrally Loaded Columns
The paper has given a detailed description of the chapter on centrally loaded columns that will appear in the 4th Edition of the Structural Stability Research Council 'Guide...
Effect of Connector Spacing on Double Angle Compressive Strength
The 1986 AISC 'Load and Resistance Factor Design (LRFD) Specification for Structural Steel Buildings' includes new rules affecting the design of built-up members...
Reliability-oriented Design of Fatigue Experiments
It is well known in the reliability analysis for structural components subjected to cyclic random load that apart from the usually model parameters uncertainties are most important and...
Fatigue Strength of Welded Wire Fabric
Long life fatigue tests were made on 12 concrete slabs reinforced with large diameter, Grade 75, deformed welded wire fabric. The specimens simulated, to full scale, conditions in a bare...
Base Isolation for Reinforced Concrete Structures
A recent experimental program has been carried out at the Earthquake Simulator Laboratory of the Earthquake Engineering Research Center in which a 1/5th scale reinforced concrete structural...
Thin Precast Fiber Reinforced Cement Panels
This paper provides an overview of some current applications, manufacturing methods, and physical properties of thin fiber reinforced cement board products currently produced. Many of...
Polymer Concrete for Structural Applications
Polymer concrete (PC) has been used extensively in the United States primarily as a repair material for portland cement concrete. The excellent flexural and compressive strength durability...
Chemical Admixtures for Concrete, What is in Them for the Structural Engineer?
The paper summarizes the effect of admixtures on the economy in construction of concrete structures, on their strength, and on their durability under a variety of service conditions. As...
High Strength Concrete - A New Material
In this paper, the material properties and structural member behavior of normal and high-strength concretes are summarized. The current ACI code recommendations are based on results of...
Structural Considerations of Cellular Concrete
Although not normally considered to be a structural material, cellular concrete possesses characteristics which may result in its having structural applications in building and structural...
Concrete Shell Design for Membrane Stress
A methodology is presented which covers the design of reinforced concrete shells for membrane stress. The methodology follows the strength design method of the ACI 318-83 Building Code...
Large Reinforced Concrete Active Reclaim Silos
The design and construction of large reinforced concrete shell silos used to provide economical short-term protected storage for coal and lignite in the active reclaim systems of power...
Ultimate Membrane Strength of R/C Shell Elements
The ultimate strength of reinforced concrete shell elements is governed by the yielding of steel and/or the compressive strength of concrete. Depending on which of these two conditions...
The Ultimate Load Design Method of R/C and P/C Shell
Based on the testing results of 20 full size shells and models, the ultimate load analysis method is proposed to design four different kinds of reinforced concrete shallow shell structures....
Second Order Analysis of a 47-Story Building
A modern day second order analysis and ultimate strength review is made of a hypothetical 47-story unbraced frame designed under the 1969 AISC Specification. The original design is part...
Return to search