Earthquake-Induced Movements and Seismic Remediation of Existing Foundations and Abutments
This proceedings, Earthquake-Induced Movements and Seismic Remediation of Existing Foundations and Abutments, contains papers presented at...

Failures in Civil Engineering
Structural, Foundation and Geoenvironmental Case Studies
This special publication consists of a collection of short descriptions of failures case studies in Civil Engineering. The descriptions cover cases in structural, foundation and geoenvironmental...

Performance of Deep Foundations Under Seismic Loading
This proceedings, Performance of Deep Foundations Under Seismic Loading, consists of papers presented at a session of the 1995 ASCE Annual...

So Your Home Is Built on Expansive Soils
Prepared by the Shallow Foundations Committee of the Geotechnical Division of ASCE. This report assists homeowners in understanding why expansive soils...

Sounding Out Scour
As engineers are aware, detection of bridge scour is the best protection. A method for monitoring scour during low, normal or high water flows would also help alleviate some of the ambiguity...

The Foundation for a New Approach to Implement Building Innovation
Prepared by the Partnership for Building Innovation project, which is sponsored by CERF; National Institute of Standards and Technology; U.S. Department of Housing and Urban Development;...

URSULA: Design of an Underwater Robot for Nuclear Reactor Vessel Inspection
This paper describes the development of an underwater robotic system that will be used to perform ultrasonic inspections of nuclear reactor vessel weldments. The development effort consists...

Design of Mat Foundation for Egg Shape Digesters
Two levels of ground motion, the Maximum Probable Earthquake and the Maximum Credible Earthquake, were considered in designing the 2.5 million gallon egg shape digesters and their combined...

Coupling Translation and Rocking Motions
In the design of concrete block foundations for rotating and reciprocating machines, it is important to avoid resonant conditions. Therefore, accurate determination of the frequencies...

Case Study - Performance of Diaphragm Walls During Construction; Predictions vs. Field Measurements
Rigid diaphragm walls (slurry walls) are being used more than any other earth supporting system for underground construction projects in confined downtown sites throughout the United States...

Seismic Evaluation of the Tied-arch Bridge Across the Mississippi River on I-40
The bridge reported in this paper is a two-span steel tied-arch bridge supported on massive caisson foundations. Site specific seismic studies were carried out to establish the ground...

Site Effects on Strong Shaking and Seismic Risk: Recent Developments and Their Impact on Seismic Design Codes and Practice
The very strong influence of localized poor or 'adverse' geological/geotechnical foundation conditions on patterns and concentrations of damage during a number of recent earthquakes (e.g.:...

Guide for the Design of Prestressed Concrete Poles
With the aim of providing engineers with some basic tools and guidelines for the design of structures, the committee prepares code and policy changes, and to expand input of manufacturers...

Overview - Electrical Substation Structures Design Guide
The ASCE Substation Structures subcommittee of the Committee on Electrical Transmission Structures (CETS) is developing a substation structures design guide. The guide discusses the analysis...

SDC Detector Foundation Requirements for the SSC
The Solenoidal Detector Collaboration (SDC) detector weighs approximately 32,000 metric tons, and its ability to perform to design specifications is directly related to its internal alignment....

High-Strain Kinetic Testing of Deep Foundations
High-strain kinetic testing involves the upward decelerating or accelerating of a mass and using its inertial force to axial prolonged pulse at the head of a pile. Currently available...

Interpretation of Nondestructive Integrity Tests Using Artificial Neural Networks
A barrier to more frequent use of nondestructive integrity tests on cast-in-place foundations is the difficulty of interpreting the test results to identify the presence or absence of...

Messeturm Tower: Frankfurt, Germany
A 256 meter (840 feet)tall office tower, currently the tallest building in Europe, has been constructed in Frankfurt Germany. The 7- story structure with 85500 square meter (920,000 square...

The Structural History of the Jacob Bachmann Tavern
The Jacob Bachmann Tavern is located in Easton, Pennsylvania. It is a collection of four interconnected buildings that have been constructed and modified over a period of 240 years. Structural...

Seismic Performance and Retrofit of the Golden Gate Bridge
Since its opening in 1937, the Golden Gate Bridge has endured and functions as an important transportation link for Bay Area commerce and commuters. After an earthquake in 1989, T.Y. Lin...

 

 

 

 

Return to search