A Fatigue Study of Prestressing Strand
Strand fatigue data reported in the literature and also from recent tests were combined to form a data base of strand fatigue data which was analyzed using regression analysis techniques....

Practical Application of PR Connections and Second Order Analysis
In the present LRFD Specifications type PR (Partially Restrained) connections are described as those where the connections of beams and girders possess an insufficient rigidity to hold...

Design of Steel Buildings for Second Order Effects
Several methods of calculating corrected effective length factors for unbraced frames are presented and discussed. In addition, an alternate format is suggested for the ASD beam-column...

Second Order Analysis of a 47-Story Building
A modern day second order analysis and ultimate strength review is made of a hypothetical 47-story unbraced frame designed under the 1969 AISC Specification. The original design is part...

Projectile Penetration Into Reinforced Concrete and Steel Targets
This paper presents brief preliminary results of a research program sponsored by the Air Force Weapons Laboratory (AFWL) to investigate the interaction of 30-mm cannon projectiles with...

Detecting Underground Piping Leaks
Most leaks from underground liquid storage systems occur in the piping rather than the tank itself. The piping system is the most vulnerable component of the system, requiring great care...

Building High Tech in China
The tallest steel structure in the People's Republic of China is being built by an international complement of designers, suppliers, vendors and contractors. It is the 42...

Sewers Get a Breath of Fresh Air
Domestic sewage pump stations and treatment facilities have long been plagued by corrosion and odor problems caused by hydrogen sulfide. It is also extremely toxic. Sulfide production...

Sewer-Septic Tank Hybrid Promises Savings
Until recently the only options for sewage were the septic tank/leach field or conventional sewers. In some cases a hybrid of the two, called the septic tank/effluent drain, is less costly...

Building Structures
This volume contains over forty papers from thirteen sessions of Structures Congress '87. The papers include a variety of topics on the overall behavior and design of buildings...

Bridges and Transmission Line Structures
This volume on Bridges and Transmission Line Structures contains papers from ten sessions and one plenary session of the 1987 ASCE Structures Congress. Eight sessions cover bridges. A...

Earthquakes Will Not Damage This Bridge
A California pipeline bridge has been retrofitted with isolation bearings that damp earthquake shocks. The bridge over Southern California's Santa Ana River carries the Upper...

Solution to a Waterhammer Problem: A Case Study
Waterhammer is caused by a rapid change in the flow velocity of liquid in a pressurized pipeline. Therefore, the potential for waterhammer exists in almost every pressurized liquid piping...

The Just-in-Case Factor
Computer analysis allows bridge designers to take a more precise look at the old structural principle of redundancy. No one can define redundancy, but everybody knows what it means. Two...

Twisting in the Wind
Wind tunnel tests are being used increasingly to test the aerodynamic stability of bridges. Many designers think these tests should be used early in the conceptual design stage, rather...

Artist in Wood Structures
Julius Natterer is chairman on the Institute for Wood Structures at the Federal Institute of Technology in Lausanne, Switzerland, and designer of more unusual or unique wood structures...

Concrete Strength Record Jumps 36%
A Seattle building now going up has 19,000 psi concrete, the strongest ever in conventional structures. It costs three times as much as conventional concrete, so will not be widely used....

Pipe-lining a Pipeline
This core prestressed concrete cylinder pipe is now lining the inside of a major water supply tunnel in Alaska. Occasionally found in rock tunnels, or buried pipelines, large diameter,...

Carmen-Smith Uprate & Modernization
The Carmen-Smith Powerhouse is located on the upper McKenzie River, 75 miles northeast of Eugene, Oregon. Carmen's two nearly identical 42. 1 MVA vertical hydroelectric turbine...

Rehabilitation of a Pump/Turbine
Between 1964 and 1968, eight 212 in pump discharge diameter Baldwin-Lima-Hamilton vertical pump/turbines with Westinghouse motor/generators were installed in Philadelphia Electric Company's...

 

 

 

 

Return to search