Towards Structural Strength and Safety Evaluation Within Bridge Management Systems
Bridge management systems being implemented by transportation departments in the United States are limited in their ability to consider structural strength and safety when preparing recommendations...

Rational Limits for Longitudinal Steel in Concrete Columns
Current limits for the amount of longitudinal reinforcement in concrete columns were established more than 60 years ago. Commercial grades of reinforcement in 1930 were about half as strong...

High-Strength Concrete Columns: State of the Knowledge
This paper consists of reported information divided into two general categories, performance of High-Strength Concrete (HSC) columns under concentric loads, and combined axial and bending...

Evaluation of Wood Floor Vibration Design Criteria
In the United States, floors in wood buildings are designed according to strength and deflection criteria under static uniform loads. With the introduction of engineered joist products...

Strength Variability of Wood Formwork Members
Failure of concrete formwork is one of the main causes of concrete construction failures. Among the main causes of formwork failure is inadequate strength. Currently there is no published...

Unified Code Provisions for Concrete Bridges
Provisions on limiting the flexural reinforcement adopted in the new AASHTO LRFD Specification for Bridge Design are summarized (1). They address minimum and maximum levels of reinforcement...

Mechanical Behavior of Dowels Embedded in Concrete
In this paper an experimental investigation on the behavior of dowels embedded in concrete is described. The dowel strength under monotonic forces with two different boundary conditions...

A Self-Balancing Laminate
A self balancing wood laminate has been developed based on the principle of orthotropic elasticity. Lumber is cut into three sections in the flatwise plane and each side member is turned...

The Effects of Bolt Over-Tightening on Bolted Connections
This paper describes a portion of the research program being conducted on structural connectors which have been over-tightened. Direct-Tension Indicators (DTI) may be specified for use...

Externally Stiffened I-Beam to Box-Column Connections
This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance...

Seismic Strengthening of URM Buildings with Steel Bracing
Unreinforced masonry (URM) buildings with large open fronts are extremely vulnerable to seismic inputs posing serious life safety hazard. Steel bracing systems have been used to upgrade...

Shear Design Guidelines for Polyester Concrete Using Recycled Plastic
Previous research on the shear behavior of steel-reinforced polymer concrete (PC) beams has been very limited and no efficient design procedures have been proposed. In all the previous...

Biaxial Testing of Brittle Repair Material for Rigid Pavements
Most codes of practice prescribe procedures for selecting patch configuration and material based on test devised for evaluating new pavement materials. This study is aimed at examined...

Testing of Hollow Clay Tile Masonry Prisms
This paper presents test results of 610-mm wide (24-in.) by 1219-mm high (48-in) by 203- or 330-mm (8- or 13-in.) thick prisms constructed of hollow clay tiles. Three prisms were extracted...

Compressive Strength of Masonry Prisms
Many factors affect the estimation of compressive capacity of a masonry prism. In the study the effects due to grout strength, mortar joints, block geometry and size, moisture content,...

Rigid Beam-To-Column Connection Detail for Circular Composite Columns
Steel pipes with relatively thin wall thickness and filled with high strength concrete have been used in building construction. Some of the advantages of this type of column include eliminating...

Development of Hardwood Glulam Timber Bridge Standards
Design standards and specification for 5.5 to 27.4 m(18 to 90 ft.) clear span hardwood glued laminated (glulam) highway bridges have been developed and are available from the Pennsylvania...

Compressive Strength of Large Scale HSLA-80 Steel Cellular Sections of a Double Hull Ship Structure
An analytical and experimental large scale test program was conducted to investigate the instability failure modes of cellular double hull box sections. The main emphasis of the study...

Field Measurements of Tensile Forces on a Spherical Dome Sector Caused by Internal Load of a Granular Product in Storage
Using a number of existing equations developed application to silos, bins, and hoppers, the horizontal load resulting from the stored product can be calculated. In this paper, the physical...

The Behaviour and Design of Stressed-Arch (Strarch) Frames
The paper presents an overview of the stressed-arch structural system and the associated research program undertaken at the University of Sydney between 1988 and 1992. The objectives of...

 

 

 

 