Beam-to-Column Connection of a Composite Structure
Composite structures can exhibit excellent performance against seismic force, and fire safety as well. However, the traditional steel reinforced concrete (SRC) system or concrete encased...
Bond Stress of Embedded Steel Shapes in Concrete
This paper describes an investigation into the bond stress developed between steel shapes and reinforced concrete when the concrete is lightly stressed. A brief discussion of previous...
Recent Developments for Composite Buildings in Japan
Research work and construction practice of composite steel and reinforced concrete structural systems in Japan are reviewed, based on the data gathered by the working group of the Architectural...
Design of Framed Steel Structures with Infill Reinforced Concrete Walls
It is a well-known fact that an infill shear wall in a frame acts as a compressive diagonal strut, giving strength and inflexibility to the frame. Recently the Architectural Institute...
Seismic Capacity Evaluation of SRC Buildings
The Japanese standard for seismic capacity evaluation of existing composite steel and reinforced concrete (SRC) buildings was introduced. As it developed, based on the previously established...
Seismic Strengthening of Existing RC Buildings
Seismic strengthening of existing reinforced concrete (RC) frame buildings by the use of steel braces or panels was studied experimentally. A special joint between steel elements and the...
Binding and Bonding Concrete to Composite Columns
Composite interaction between concrete encasement and structural steel shapes is limited unless lateral ties and/or mechanical attachments insure such interaction until desired strength...
Reshaping the Future of Plastic Buildings
Plastic structures have been around for 40 years, but have for the most part been showcases with little use in the mainstream of the building industry. To be used effectively, plastics...
A Road to Recovery
Inspections of the Golden Gate Bridge revealed that the bridge had localized corrosion near its expansion joints, corrosion of its reinforcing steel, and was severely contaminated with...
Modular Plastic Media for Shallow Bed Trickling Filter Applications
Little specific data is available for less sophisticated trickling filter systems which employ recent plastic media designs for shallow bed filters without the added cost of subsequent...
Metal and Plastic Pipelines: Design and Construction Aspects
This paper discusses design and construction aspects of four cross-country pipelines that were built in central Alberta, Canada during 1982-1983. The first two pipelines, carrying different...
Failure of a Large Reinforced Concrete Pipeline
This paper describes the damage that occurred when a landslide overloaded an 11 ft diameter reinforced concrete pipeline. The 8 ft lengths of pipe, each of 11. 5-in. wall thickness, were...
Field Burial Tests of Corrugated Double Wall PVC Pipe
A new lightweight PVC pipe, consisting of a smooth inner wall and a corrugated outer wall, has been introduced in the U. S. sanitary sewer market in 4 through 10 in. diameters. Field burial...
Stiffness Requirements for HDPE, Profile Wall Pipe
For the past two years the Gulf Oil Corporation has sponsored a research study on profile wall High Density Polyethylene (HDPE) pipe at Texas A & M University. A pipe design computer...
Investigation of the Long-Term Creep Modulus for Buried Polyethylene Pipes Subjected to Constant Deflection
The tests reported in this paper are simulating the stress relaxation in constantly deflected pipe rings of various high density and medium density polyethylene grades. The pipe rings...
Long Term Deflection of Buried Plastic Sewer Pipes
During the 70's and the early 80's a research program has been carried out in Sweden regarding the long term behaviour of buried plastic pipes. The program has...
The Relative Strain as a Design Criterion for Buried uPVC Gravity Sewer Pipes
When designing buried plastic sewer pipes, the relative strain caused by deflection of the circular pipe section is of particular interest. The reason for increased interest is the present...
Buried Fiberglass Pipe Response to Field Installation Methods
In 1970 near Yuma, Arizona, a field test installation of 30 inch diameter fiberglass pipe was constructed. Twelve years later the pipeline was remeasured. Measurements of pipe profile,...
Strains Induced by Combined Loading in Buried Pressurized Fiberglass Pipe
In 1983 Owens Corning Fiberglas and Utah State University collaborated on a study of combined strain behavior of fiberglass pipe to quantify the bending strain reduction as a function...
Long Term Testing of Centrifugally Cast Glass Fibre Reinforced Plastic Pipes (RIRP)
The paper discusses testing of pipe manufactured by centrifugal molding. The tests included external load tests, internal load, hydrostatic internal pressure, and cyclic internal pressure....