High Quality Sampling and In Situ Testing for Deep Water Geotechnical Site Investigation
This paper discusses methods that have been used to conduct geotechnical investigations in water depths up to 2500 feet. Investigations can be conducted from supply boats, geotechnical...

Effect of Cementation on the Cone Penetration Resistance of Sand
A laboratory study was conducted to investigate the effect of cementation on the cone penetration resistance of sand. A new apparatus to form homogeneous artificially cemented sand specimens...

In Situ Measurement of Permeability in Soft Clays
As part of an extensive field programme, the magnitude of errors due to clay remoulding and filter clogging in tests performed in common piezometers is evidenced. Comparisons between variable...

The Mudslide Profile Method to Measure the Undrained Shear Strength of Muds
Mudslides have been reported to have a very distinctive profile. Using this distinctive profile, a method is presented to analyze the stability of the mudslide at limit equilibrium conditions....

Interpretation of CPT Data for Design of Earth Dams Near Tehachapi, California
The Static Cone Penetration Test (CPT) was used to obtain needed geotechnical information for design and construction of two small earth dams near Tehachapi, California. The basic CPT...

The Use of Cone Penetrometer Testing to Investigate Sand Fill Subsidence Beneath Highways
During construction of Interstate I-10 between Baton Rouge and LaPlace, Louisiana, highly organic swamp deposits were excavated and replaced with hydraulically pumped river sand. The main...

In Situ Tests for Foundation Vibrations
There are several well established methods of determining shear modulus in situ and these are summarized in this paper. New techniques are being developed for in situ determination of...

Comparison Between In-Situ Test Results
Penetration tests provide a means of obtaining data from which estimations can be made of the bearing capacity, settlement and liquefaction potential of the soils tested. Empirical formulae...

Parking Lot Gets White Top
The many-acre parking lot at the Valley Fair Mall shopping center in Salt Lake City, Utah is described. In 1985 the asphalt pavement was overlaid with concrete, making it one of the relatively...

New Approaches to Rehabbing Old Dams
The U.S. Bureau of Reclamation takes a look at several new ways of building old dams for maximum flooding. A labyrinth spillway was built at Ute Dam near Logan, N.M. to increase reservoir...

Putting Wastewater to Work
Although the central Florida city of Altamonte Springs sits on one of the world's most productive aquifers, the Floridan Aquifer, the town is investing $35 million in a system...

Tunnel Ceiling Replaced over traffic
The ceiling of the Holland Tunnel under the Hudson River, connecting New Jersey and Manhattan, was 59 years old and needed replacement, a big job because there are 3 miles of ceiling in...

Field Study of Specialized Bacteria for Nitrification
A full scale field study using specialized bacteria was conducted to determine its effectiveness in achieving nitrification while quantifying dosage rates. A side-by-side comparison of...

Comprehensive Odor Control Programat East Bay Municipal Utility District (SD-1)
An odor control study was performed in a wastewater treatment plant in California to evaluate the interactive role of various factors tailored to site specific conditions. The scope of...

Radium Removal from Groundwater Using Sorption to Filter Sand
The use of this novel process to remove sufficient radium from drinking water by filter sand has been demonstrated. A major potential advantage of this process is that a minimal capital...

Contaminated Well Field Study Case History: West Milford Township
The contaminated well field program initiated by the NJDEP has proven effective in enabling a rapid response to a wide variety of water supply and groundwater contamination problems as...

Design Considerations and Experiences with VOC Treatment Technologies
This paper presents a review of design considerations and experiences with packed column aeration for removal of volatile organic chemicals (VOC) from groundwater at various locations...

Ft. Lauderdale Wellfield Protection
Results of the study on groundwater contamination measurement and control are reported. The goal of this study was to ensure a safe and long-term supply of drinking water to the City of...

Testing of Permeable Materials for Retaining Contaminants in Subsurface Leachates
The use of a permeable, retentive treatment system could remove both organic and inorganic contaminants while still allowing flow. A testing procedure for determining the amounts of priority...

Permeability of Grouts Subjected to Chemicals
This paper presents the more recent results of a testing program which evaluated the long-term resistance to percolation of grouted soils, using acrylate, urethane and cement-bentonite...

 

 

 

 

Return to search