Strengthening of a Multi-Story Building with Deflection Constraints
Occasionally the existing structural or nonstructural systems of a building being strengthened require the imposition of deflection constraints or limits in order to avoid an undesirable...
Regional Risk Assessment of Existing Buildings
This paper describes current research underway at Stanford University designed to develop a methodology for determining high risk buildings in a region. The work involves developing a...
On Reliability-Based Structural Optimization for Earthquakes
Previous studies of reliability-based structural optimization have been extended in order to investigate the applicability of the linear statistical model in cases where random parameters...
Seismic Restraint of Hazardous Process Piping
The lack of appropriate guidelines for the design and installation of hazardous process piping in industrial facilities has created a potentially dangerous situation. Process piping carrying...
Wind Loads and Building Response Predictions Using Force Balance Techniques
The use of force balance techniques to measure mean and dynamic wind loads on models of buildings and structures is discussed. Advantages of using force balance techniques over estimating...
Modeling 3-D Response in R/C Frame-Wall Structures
As part of the recent U. S. -Japan Cooperative Research Program on the seismic performance of buildings, a 1/5-scale model of a 7-story reinforced concrete frame-wall structure, was constructed...
Building Identification: Needs and Means
The need to conduct 'system identification' of existing buildings by nondestructive testing is discussed. A recommended flow-chart is exemplified. Existing dynamic...
Earthquake Response Simulation Capacity of Pseudo Dynamic Testing?Experimntal Demonstration and Analytic Evaluation
The response accuracy of the pseudo dynamic test was evaluated from the shake table and pseudo dynamic tests conducted for a two story steel braced frame model. The obtained responses...
Evaluation of Seismic Strengthening of an Existing Building Using Base Isolation
This paper summarizes a study performed by Englekirk and Hart, Inc. to evaluate the feasibility of using base isolation to seismically upgrade an existing highrise building. To realize...
Earthquake Response of Five Story Reinforced Concrete Masonry Test Building
In 1986, a full-scale five story reinforced masonry test building is to be constructed in the Japan Building Research Institute Large-Scale Structure Test Laboratory, and through 1987...
Research Topics in Structural Identification
The authors examined a variety of possible research topics including identification and detection of nonlinearities, model improvement approaches, damage identification, power estimation...
Soil-Structure Interaction at the Waterfront
In 1981 the Naval Civil Engineering Laboratory (NCEL) undertook a review of available material models. Comparison was made between test data and model predictions. Based on this study,...
Rigid Body Random Rocking Prediction
The stochastic rocking of a rigid block due to shaking of its foundation is examined. The foundation is flexible (Winkler) and its independent springs and dashpots separate from the block...
Dynamic Response of Systems with Uncertain Properties
This paper addresses the methodology for determining the response of a structure modelled as single-degree-of-freedom system whose mass, damping and stiffness parameters are known only...
Modeling for Finite-Element Soil-Structure Interaction Analysis
The modeling for finite-element soil-structure interaction analysis for embedded structures is evaluated in an attempt to resolve the issue related to the elevation at which design ground...
An Experimental Study of Active Structural Control
An experimental investigation is made concerning the possible application of active control to structures under seismic excitation. The experimental facilities and structural model are...
Dynamic Behavior of Full-Scale Wood Diaphragms
Experimental testing of full-scale wood diaphragms has been performed at Washington State University to determine basic dynamic properties. Ten diaphragms, including walls, floors, and...
Cladding Design for Tall Buildings
In the past twenty years, glass cladding has emerged as a popular and economic building material. Its use in tall buildings which are constructed in high-risk wind and seismic geographical...
Ambient Vibration Testing of the Foothill Communities Law and Justice Building
This paper presents the results of two ambient vibration tests conducted on the Foothill Communities Law and Justice Center Building. One ambient test was performed in 1985. The second...
The Atlantic Palace?Part II The Application of Wind Tunnel/Force Balance Techniques
A relatively new approach for determining overall wind-induced loads on a structure is described. This force balance technique is economical and flexible, and able to provide predictions...