Externally Stiffened I-Beam to Box-Column Connections
This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance...
Investigating the Behavior of a Lattice Structural Section
Tests were conducted on a fully instrumented lattice section assembled using various connection types (bolted or welded). The results of this study show that bolt slippage can have a major...
Practical Application of Tuned Liquid Damper for Tall Buildings
Performance of TLD, based on the full-scale measurement of an actual tall building, is discussed in this paper. Wind induced vibration of the SYP Tower was measured during a gusty day,...
Fires Deemed to Have Tested Structural Performance
This paper provides an overview and progress report of a survey and study of fire incidents deemed to have tested the structural performance of large buildings. This ongoing effort was...
Consequential Fire Loads on Structures
Much less consideration has been given to the performance of modern structural and architectural systems during fires and to the minimization of damage that threatens the integrity of...
Synopsis of a Manual on Structural Fire Protection
Structural Fire Protection : Manual of Practice was published in 1992 by the American Society of Civil Engineers. The Manual has two major parts. Part I (Chapters 1 to 3) introduces the...
Estimation of Structural Damping of Buildings
The full-scale data on damping ratio are collected from 77 buildings within Japan. Almost all data are obtained from vibrations with a very small amplitude such as microtremor, man-power...
Earthquake Barrier Technology: Sliding-Friction Energy Dissipation
The first project in America to use friction damping was approved by the City of Los Angeles for the retrofit of a 10-story concrete frame building, designed to resist a Maximum Credible...
Wind Loads on Low Rise Structures: A Survey
Because of the large investment, high rise buildings are usually tested in a wind tunnel to provide the best wind loading information possible. Since low rise structures each represent...
A Statistical Analysis of Wind Damage to Single-Family Dwellings Due to Hurricane Hugo
The claim files of 575 policy holders of the South Carolina Windstorm and Hail Underwriting Association were analyzed to determine the nature of wind damage to single-family dwellings...
Diaphragm Action of Cladding in Low-Rise Metal Buildings
An investigation of the contribution of cladding to the lateral stiffness of a metal building is presented in this paper. The diaphragm action of the cladding tends to redistribute the...
Uplift Resistance of Plywood and OSB Roof Sheathing
A test program to determine the resistance of plywood and OSB roof sheathing to uplift pressures created by wind flowing over a residential roof structure will provide valuable data to...
Behavior of Tall Frame Combining Rigid and Semi-Rigid Connections
In this paper, the applicability of the mixed use of rigid and semi-rigid connections in the tall frame is discussed. It is tried. for 4-bay 8-storey frame to be numerically analyzed for...
Bridging the Gap Between Architecture and Engineering
Building design is interdisciplinary by nature. Indeed, the collaboration of architect and structural engineer is critical to the success of building design projects. Yet with few exceptions...
Aesthetic Issues in Timber Bridges
The vocabulary of visual design and several generally accepted major principles of visual design are reviewed in order to provide a 'context' for case studies of award-winning timber bridges....
Implementation of Passive Energy Dissipation Systems in the United States
Significant advances in the field of passive energy dissipation for improved structural seismic resistance have been made in recent years. Developments in research and analysis techniques...
Utilizing Visco-Elastic Dampers in the Seismic Retrofit of a Thirteen Story Steel Framed Building
A 13 story steel framed building in Santa Clara Country, California exhibited strong beating effects (torsional coupling) and prolonged building response as result of various seismic events....
When are Loads Taught? A Case Study and National Trends.
Several years ago, structures faculty of the Department of Civil and Architectural Engineering at the University of Wyoming revised their structures courses to meet several new educational...
Where do the Arrows Come From? Evaluating Structural Loads
Two elements of an undergraduate's structural education that are not treated well in most textbooks are (1) the development of correct loads and (2) load modelling-that is, how the load...
Long-Term Monitoring of Civil Structures using Smart Structures Techniques
A smart monitoring program for a hybrid concrete-steel building in Washington, D.C. has been developed. The building is currently being instrumented with a variety of strain and corrosion...
Return to search