Abstract:

Tests were conducted on a fully instrumented lattice section assembled using various connection types (bolted or welded). The results of this study show that bolt slippage can have a major impact on member force prediction, and consequently, affect member design.



Subject Headings: Steel structures | Structural analysis | Bolted connections | Structural design | Lattices | Building design | Power transmission lines