Shear Design Guidelines for Polyester Concrete Using Recycled Plastic
Previous research on the shear behavior of steel-reinforced polymer concrete (PC) beams has been very limited and no efficient design procedures have been proposed. In all the previous...
Dynamic Response of Steel Fiber Reinforced Concrete
Extensive research has been done on the static properties of steel fiber reinforced concrete, but very little on the dynamic properties. A total of 20 beams was tested. The steel fiber...
Fatigue Damage Accumulation Under Stochastic Stress Histories
An extensive simulation study was performed to generate random Gaussian stress time histories from power spectral densities (psd's). The psd's of time histories were selected to represent...
Characterization of an ER Active Member
In the presence of strong electric fields (kV/mm), electrorheological (ER) materials change form viscous fluids to yielding materials. The class of ER materials used in this study have...
Fracture Analysis of Bolted Timber Connections
Application of fracture mechanics concepts to splice connections where bolts load timber members perpendicular to the grain is discussed. Attention is given to prediction of the load level...
Special Considerations in the Design of Connections for Recycled Wood/Plastic Composite Lumber
There is current work in the American Society for Testing and Materials (ASTM) to evaluate potential test methods for what they refer to as 'commingled' plastic lumber. This category covers...
Low Strain Dynamic Testing of Wood Piles Supporting an Existing Pier
This paper presents a case history where low strain dynamic testing was performed to test wood piles supporting an existing structure. Under consideration is a 183 m long wooden pier constructed...
Some Aspects of Determination of Pile Capacity by the Wave Equation
This paper presents some new observations made during correlation study of pile capacity computed by wave equation analysis with failure load from static test. In order to determine proper...
Biaxial Testing of Brittle Repair Material for Rigid Pavements
Most codes of practice prescribe procedures for selecting patch configuration and material based on test devised for evaluating new pavement materials. This study is aimed at examined...
Control of Random Crack Formation in Portland Cement Concrete Pavements
Random crack formation in concrete pavements, which is mainly due to the development of tensile stress caused by temperature-induced volumetric change and shrinkage deformation at early...
Synopsis of a Manual on Structural Fire Protection
Structural Fire Protection : Manual of Practice was published in 1992 by the American Society of Civil Engineers. The Manual has two major parts. Part I (Chapters 1 to 3) introduces the...
Diaphragm Action of Cladding in Low-Rise Metal Buildings
An investigation of the contribution of cladding to the lateral stiffness of a metal building is presented in this paper. The diaphragm action of the cladding tends to redistribute the...
Compressive Strength of Masonry Prisms
Many factors affect the estimation of compressive capacity of a masonry prism. In the study the effects due to grout strength, mortar joints, block geometry and size, moisture content,...
Seismic Analysis of Failure and Loss of Function of Water Pumping Facilities
Water company managers evaluating potential seismic damage effects on a pumping facility will require a reasonable estimate of the probable magnitude earthquake that has potential to disrupt...
Seismic Response and Retrofitting of Non-Ductile Reinforced Concrete Bridges
The Interstate I5/I605 Separator in Los Angeles County was severely damaged during the October, 1 1987 Whittier Narrows Earthquake. This damage included non-ductile shear failure in the...
Testing of Concrete Curtain Wall Panels Reinforced with FRP Grids
The objective of this paper is to evaluate the suitability of Fiber Reinforced Plastic (FRP) grids for use as a structural; reinforcement in concrete curtain wall panels. This paper describes...
Development of Hardwood Glulam Timber Bridge Standards
Design standards and specification for 5.5 to 27.4 m(18 to 90 ft.) clear span hardwood glued laminated (glulam) highway bridges have been developed and are available from the Pennsylvania...
Design and Field Performance of a Metal-Plate-Connected Wood Truss Bridge
This paper describes an on-going study on the design and performance attributes of an experimental wood-truss bridge. This is believed to be the first roadway bridge application of metal-plate-connected...
Bulb-T and Glulam-FRP Beams for Timber Bridges
In this paper, we discusses the manufacturing, analysis, and testing of two glulam beam designers:(1) Southern pine bulb, and (2) yellow-poplar reinforced with pultruded fiber-reinforced...
Anchorage of Non-Metallic Prestressing Tendons
Experimental confirmation tests were conducted to evaluate mechanical and epoxy socketed anchors for fiber reinforced plastic (FRP) prestressing tendons. The studies found that a parabolically...
Return to search