Statistical Response of a Class of Hysteretic Systems
The response of a hysteretic nonlinear system subjected to a filtered white noise is considered. The method of time-dependent equivalent linearization is used and the moment equations...

FRP Box-Beams Under Long-Time Static and Fatigue Loading
This paper discusses experimental and analytical aspects of the long-time behavior of filament wound E-glass fiber reinforced epoxy-box-beams. Theoretical and experimental data are compared...

Rational Limits for Longitudinal Steel in Concrete Columns
Current limits for the amount of longitudinal reinforcement in concrete columns were established more than 60 years ago. Commercial grades of reinforcement in 1930 were about half as strong...

High-Strength Concrete Columns: State of the Knowledge
This paper consists of reported information divided into two general categories, performance of High-Strength Concrete (HSC) columns under concentric loads, and combined axial and bending...

Evaluation of Wood Floor Vibration Design Criteria
In the United States, floors in wood buildings are designed according to strength and deflection criteria under static uniform loads. With the introduction of engineered joist products...

Strength Variability of Wood Formwork Members
Failure of concrete formwork is one of the main causes of concrete construction failures. Among the main causes of formwork failure is inadequate strength. Currently there is no published...

Design Guidelines for the Use of Debonded Strands
In this paper, presented are the flexural tests performed on beams containing debonded strands. Results show that debonded strands can be used reliably and safely, stipulating that the...

Development Length of Uncoated Prestressing Strand
The Federal Highway Administration is conducting ongoing research which investigates the development length of uncoated and epoxy coated prestressing strand in prestressed concrete members....

Mechanical Behavior of Dowels Embedded in Concrete
In this paper an experimental investigation on the behavior of dowels embedded in concrete is described. The dowel strength under monotonic forces with two different boundary conditions...

A Self-Balancing Laminate
A self balancing wood laminate has been developed based on the principle of orthotropic elasticity. Lumber is cut into three sections in the flatwise plane and each side member is turned...

Metal Truss Plates: Less than Full-Depth Penetration and Shear Buckling
This paper presents the results of two experimental studies on metal truss plates which are used to join members of wood trusses. The first study investigated the effect that less than...

Natural Decay Resistance of Glued-Laminated Beams
The natural decay resistance of untreated Douglas-fir heartwood specimens sampled from glued-laminated beams was evaluated using a modified agar plate test modeled after the European Standard...

The Effects of Bolt Over-Tightening on Bolted Connections
This paper describes a portion of the research program being conducted on structural connectors which have been over-tightened. Direct-Tension Indicators (DTI) may be specified for use...

Externally Stiffened I-Beam to Box-Column Connections
This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance...

ATLSS Connections with Moment Capacity
ATLSS Connections are a family of beam-to-column connections which utilize the self-aligning feature of a specially designed connector and are developed for possible use in an automated...

The Challenge of Housing the Largest Detector
The most innovative part of the structural-civil design of the Superconducting Super Collider (SSC) is that of the underground experimental halls located alongside the 86 kilometer collider...

High Strength Shotcrete and Concrete on the SSC Project
This paper addresses the technical aspects related to the use of high strength shotcrete and concrete on the Superconducting Super Collider (SSC) project. 7,000 psi shotcrete and 8,000...

Steel-Concrete Interaction by Means of Film Sensors
By adapting a recently-developed technique based on the piezoelectrical properties of relatively thick films made of Polyvinyldifluor organic composites and extensively used in robotics,...

Shear Design Guidelines for Polyester Concrete Using Recycled Plastic
Previous research on the shear behavior of steel-reinforced polymer concrete (PC) beams has been very limited and no efficient design procedures have been proposed. In all the previous...

Dynamic Response of Steel Fiber Reinforced Concrete
Extensive research has been done on the static properties of steel fiber reinforced concrete, but very little on the dynamic properties. A total of 20 beams was tested. The steel fiber...

 

 

 

 

Return to search