Bridging Twin Ports
The Major Richard I. Bong Memorial Bridge, part of U. S. Highway 2, connects harbors at Duluth, Minn. and Superior, Wisc. The new highway link was designed to relieve congestion on nearby...

Who Should Design Bridges?
For many years Design-Build-Proposals have been common practice in Europe (except in the UK). Structures in these countries are 20% more economical than similar projects in the U. S.,...

Metal and Plastic Pipelines: Design and Construction Aspects
This paper discusses design and construction aspects of four cross-country pipelines that were built in central Alberta, Canada during 1982-1983. The first two pipelines, carrying different...

SPIDA: An Analysis and Design System for Buried Concrete Pipe
The paper presents a description of a new computerized direct design method for buried concrete pipe named SPIDA (Soil-Pipe Interaction Design and Analysis). Also the technical basis and...

Field Burial Tests of Corrugated Double Wall PVC Pipe
A new lightweight PVC pipe, consisting of a smooth inner wall and a corrugated outer wall, has been introduced in the U. S. sanitary sewer market in 4 through 10 in. diameters. Field burial...

Stiffness Requirements for HDPE, Profile Wall Pipe
For the past two years the Gulf Oil Corporation has sponsored a research study on profile wall High Density Polyethylene (HDPE) pipe at Texas A & M University. A pipe design computer...

Investigation of the Long-Term Creep Modulus for Buried Polyethylene Pipes Subjected to Constant Deflection
The tests reported in this paper are simulating the stress relaxation in constantly deflected pipe rings of various high density and medium density polyethylene grades. The pipe rings...

Long Term Deflection of Buried Plastic Sewer Pipes
During the 70's and the early 80's a research program has been carried out in Sweden regarding the long term behaviour of buried plastic pipes. The program has...

The Relative Strain as a Design Criterion for Buried uPVC Gravity Sewer Pipes
When designing buried plastic sewer pipes, the relative strain caused by deflection of the circular pipe section is of particular interest. The reason for increased interest is the present...

Buried Fiberglass Pipe Response to Field Installation Methods
In 1970 near Yuma, Arizona, a field test installation of 30 inch diameter fiberglass pipe was constructed. Twelve years later the pipeline was remeasured. Measurements of pipe profile,...

Strains Induced by Combined Loading in Buried Pressurized Fiberglass Pipe
In 1983 Owens Corning Fiberglas and Utah State University collaborated on a study of combined strain behavior of fiberglass pipe to quantify the bending strain reduction as a function...

Long Term Testing of Centrifugally Cast Glass Fibre Reinforced Plastic Pipes (RIRP)
The paper discusses testing of pipe manufactured by centrifugal molding. The tests included external load tests, internal load, hydrostatic internal pressure, and cyclic internal pressure....

Buried Fiberglass Pipe Performance and Installation Requirements and Design Calculations in International Standardization
This paper elaborates on a proposed standard covering details of fiberglass pipe buried installation requirements and criteria for selection of pipe stiffness. It also discusses the selection...

KEMCOR?A Chemical and Corrosion Resistant Piping System
KEMCOR is a new underground composite pipe system designed for chemical process use in such industries which require a high degree of corrosion resistance to varying concentrations and...

Field Testing of 84-Inch-Diameter Plastic Pipe
During the summer of 1981, a research project was initiated to monitor strains and deformation in 84-inch diameter RPM (reinforced plastic mortar) pressure pipe. Three 20-foot (6. 1-m)...

Response of Buried Flexible Plastic Conduits Under Loading
Structural performance of 75 mm and 100 mm diameter plastic conduits embedded in Lloyd clay were examined experimentally in a laboratory soil bin, and numerically by the finite element...

Large Diameter Plastic Pipe Design
This paper presents a rationale for the design of large diameter plastic pipes for gravity flow applications. This procedure, applicable for all plastic pipes, adapts state-of-the-art...

Successful Use of Centrifugally Cast Glassfiber Reinforced Plastic (GRP) Pressure Pipes for Public Works in Sweden
Centrifugally cast GRP pipes were introduced in Sweden 17 years ago for industrial applications mainly as a gravity pipe. The process of pipe manufacturing as well as the pipe itself and...

Design of Non-Pressure Very Flexible Plastic Pipe
There is considerable debate about the correct structural design procedure to be used for very flexible plastic pipe (VFP) - typically glass-fiber reinforced pipe (GRP), reinforced plastic...

Influence of Frost Action on the Load Exerted on Buried Pipe
When work was started on revising the Swedish code for concrete pipes at the end of the 70's, a research project was carried out to evaluate the risk of increased load due...

 

 

 

 

Return to search