On the Critical Relative Displacement of Pile Shaft and Surrounding Soil
Model pile pull-out tests have been conducted to investigate the characteristics of the critical relative displacement at which the critical pile skin resistance is mobilized. Test results...

The Influence of Cyclic Loading on the Lateral Load Response of Groups of Piles
The effects of cyclic loading on the lateral response of closely spaced groups of piles has been widely considered to be a single pile phenomenon, related to gapping and scour around the...

Investigation and Modeling of Soil-Structure Interface Properties
An investigation of some techniques suggested to reduce friction at the soil-structure interface, for example plastic sheet on sand, is presented, and a model proposed for characterizing...

Settlement of Single Piles
This paper presents an application of a recently developed approach for computing the tip settlement of axially loaded single piles driven into compressible layered soil system. In this...

Numerical Analysis of Vertically Loaded Pile Groups
An approach is presented for the analysis of linear and nonlinear response of vertically loaded pile groups. The piles are modeled with finite elements, the pile-soil influence through...

Effect of Site Soil Properties on Seismic SSI Response of Embedded Structures
In a series of two-dimensional soil-structure interaction (SSI) analyses, seismic responses, including the SSI effect of a deeply embedded reactor building of a standard plant in different...

Seismic Response Study of Two Memphis Sites
This paper presents a study to evaluate the soil effects on earthquake ground motion of two selected sites in the Memphis area. Twenty artificial bedrock acceleration time histories with...

Simplified Seismic Analysis of Pile Foundations
The determination of displacement of the pile cap and displacements and forces of individual piles is essential to the design of pile foundation subject to both static and/or dynamic loading....

Seismic Response Considerations in Foundation Design
There are no generally accepted procedures to determine the potential magnitude of reduction of footing bearing capacity that may result from soil strains or pore pressure changes during...

Analysis of Pile Load Tests at Lock and Dam 26
This is a summary of the results collected during the extensive load test program performed by the U.S. Army Engineer District, St. Louis, during the construction of the new Lock and Dam...

Comparative Performance of Two Pile Types
This paper reports on the pile driving and load bearing characteristics of the two pile types driven at a plant site in Sumatra, Indonesia. Nine prestressed concrete piles were driven...

Bearing Pressure?SPT Correlations for Expanded Base Piles in Sand
Design of enlarged base piles is usually carried out using correlations between SPT N values and point resistance. The results of full scale load tests are used to show that base resistance...

Contribution of Soil Freeze to Pile Capacity
In order to investigate the magnitude and rate of increase in load capacity for piles installed in clayey soils, a series of load tests were performed at various intervals of time following...

New Design Method for Drilled Shafts from Common Soil and Rock Tests
A method is presented by which the compressive capacity and load-settlement characteristics of large drilled shafts can be computed from commonly executed soil and rock tests. The method...

Performance of High Capacity Caissons Founded on Decomposed Rock
The results of six load tests on large diameter caissons founded on decomposed rock are presented and analyzed. The caissons ranged from 1.5 m to 2.5 m in diameter and were 20 m to 23...

Load Tests on Bored Friction Piles in Clay
For the first time in Boston, Massachusetts, U.S.A., uncased bored friction piles in clay were used to support a six-story residential structure over a 60- to 75-foot (1.83 to 22.9 m)...

Skin Friction Load Test for Caissons in Residual Soils
Results of a load test on a drilled pier are presented. The test was performed to measure only skin friction of a 36 inch (0.91 m) diameter shaft without support at the end. The load test...

Full Scale Caisson Load Test for the Milwaukee Center
Top-down procedures were proposed to construct four basement levels for a major high-rise building development in Milwaukee, Wisconsin. Drilled caisson foundations were the preferred means...

Drilled Shafts?A Database Approach
A database of 43 drilled shaft load tests of high quality has been developed to study parameters that affect the axial behavior of drilled shafts and methods of analysis to predict axial...

Caissons in Uplift in Sandy Soils
This paper describes the results of 10 full scale pullout tests conducted on short rigid caissons. Diameters ranged from 30 to 34 inches (760 to 860 mm) and lengths from 7 to 10 feet (2.1...

 

 

 

 

Return to search