Optimal Collection of Data for Parameter Identification
In this paper, the author attempts to study the optimal spacing of measurements for a structural system modelled by a single-degree-of-freedom oscillator so that the variance of one or...
Dynamic Response Moments of Random Parametered Structures with Random Excitation
First and second order statistical response moments are formulated for linear multi-degree of freedom dynamical systems having both random load and random structural characteristics. A...
Dynamic Response of Systems with Uncertain Properties
This paper addresses the methodology for determining the response of a structure modelled as single-degree-of-freedom system whose mass, damping and stiffness parameters are known only...
Stochastic Response of Structures with Appendages Containing Fluids
Following a perturbation technique a procedure is developed to compute the modal properties of a system consisting of a fluid containing appendage attached to a multi-degree-of-freedom...
Active Control of Distributed Parameters Structures by Pointwise Control Actions
Several methods have been offered to control a structure. These methods are the optimal control, the pole assignment, the independent modal space control, and the direct velocity feedback....
Optimal Control of Seismic Structures
This paper presents the algorithm for optimal design of structural systems with active tendon controllers and/or active mass dampers. The structure is subjected to earthquake excitation...
Application of Modern Control Theory for Building Structures
Active control systems can be used to reduce the effect of strong-motion earthquakes. During the past two decades, various approaches have been applied to find the optimal control law....
Dynamic Response of Highway Guardrail Post Foundations
The highway departments use two types of guardrail posts: a circular wood post and a steel W6 multiplied by 8. 5 post. The current specifications require the steel post to be placed in...
Cladding Design for Tall Buildings
In the past twenty years, glass cladding has emerged as a popular and economic building material. Its use in tall buildings which are constructed in high-risk wind and seismic geographical...
Response of Underground Pipelines to Dynamic Loads
The results of an investigation of the forced response of an underground pipeline due to dynamic loads are presented. The pipe is modelled as a linearly elastic shell element and the surrounding...
Seismic Isolation of Bridge Structures
Seismic isolation concept has been extensively developed and applied in New Zealand and is receiving increased attention in the United States. Two bridge projects have incorporated the...
Interdependence of Dynamic Analysis and Experiment
This paper emphasizes the importance of experimental research to the development of reliable analytical methods for predicting the behavior of structures subjected to static or dynamic...
The Atlantic Palace?Part II The Application of Wind Tunnel/Force Balance Techniques
A relatively new approach for determining overall wind-induced loads on a structure is described. This force balance technique is economical and flexible, and able to provide predictions...
The Atlantic Palace: Part I Structural System Selection Based on Wind Tunnel Testing
The location of the structure in a coastal area susceptible to high winds, the irregular shape and height of the building and the desire for more accurate wind loading and acceleration...
Settlement of Light Buildings on Loose Sand
This paper reviews several cases of settlement of lightly loaded structures supported on granular soils. The concept of settlement ratio is presented. Measurements indicate that the settlement...
Large Scale Testing Facility for the Evaluation of Structural Systems Under Critical Loads
The Charles Lee Powell Structural Systems Laboratory at the University of California, San Diego, provides, with a 50 ft. high reaction strong wall and a 120 multiplied by 50 ft. box girder...
Experimental Studies, Structural Design and Full-Scale Measurements for the Columbia Seafirst Center
The Columbia Seafirst Center is a 76-story office tower located in downtown Seattle, Washington. It rises to a height of about 940 feet above ground and is the world's 10th...
Comparison of Predicted and Measured Dynamic Behavior of Allied Bank Plaza
Structural engineering aspects of a monitoring program to measure Allied Bank Plaza tower's dynamic response to wind are presented. In particular, field data developed during...
Design of Viscoelastic Dampers for Columbia Center Building
To reduce the dynamic response of a building with a given height and plan area to wind load, aside from inherent damping of the building, the designer has a few options available to him/her....
Blasting Densifies Sand
Constructing the Jebba Dam on Nigeria's Niger River required in-place densification of large volumes of loose sand to record depths of up to 131 ft. Vibrocompaction was used...