Stochastic Response of Structures with Appendages Containing Fluids
Following a perturbation technique a procedure is developed to compute the modal properties of a system consisting of a fluid containing appendage attached to a multi-degree-of-freedom...
Optimal Control of Seismic Structures
This paper presents the algorithm for optimal design of structural systems with active tendon controllers and/or active mass dampers. The structure is subjected to earthquake excitation...
Application of Modern Control Theory for Building Structures
Active control systems can be used to reduce the effect of strong-motion earthquakes. During the past two decades, various approaches have been applied to find the optimal control law....
An Experimental Study of Active Structural Control
An experimental investigation is made concerning the possible application of active control to structures under seismic excitation. The experimental facilities and structural model are...
Dynamic Response of Highway Guardrail Post Foundations
The highway departments use two types of guardrail posts: a circular wood post and a steel W6 multiplied by 8. 5 post. The current specifications require the steel post to be placed in...
Cladding Design for Tall Buildings
In the past twenty years, glass cladding has emerged as a popular and economic building material. Its use in tall buildings which are constructed in high-risk wind and seismic geographical...
Response of Underground Pipelines to Dynamic Loads
The results of an investigation of the forced response of an underground pipeline due to dynamic loads are presented. The pipe is modelled as a linearly elastic shell element and the surrounding...
Seismic Isolation of Bridge Structures
Seismic isolation concept has been extensively developed and applied in New Zealand and is receiving increased attention in the United States. Two bridge projects have incorporated the...
Hysteretic Behavior of Precast Cladding Connections
A preliminary experimental study is presented which investigates the behavior of connections for architectural precast concrete cladding panels. The principal objective is to quantify...
Interdependence of Dynamic Analysis and Experiment
This paper emphasizes the importance of experimental research to the development of reliable analytical methods for predicting the behavior of structures subjected to static or dynamic...
Ambient Vibration Testing of the Foothill Communities Law and Justice Building
This paper presents the results of two ambient vibration tests conducted on the Foothill Communities Law and Justice Center Building. One ambient test was performed in 1985. The second...
The Atlantic Palace?Part II The Application of Wind Tunnel/Force Balance Techniques
A relatively new approach for determining overall wind-induced loads on a structure is described. This force balance technique is economical and flexible, and able to provide predictions...
The Atlantic Palace: Part I Structural System Selection Based on Wind Tunnel Testing
The location of the structure in a coastal area susceptible to high winds, the irregular shape and height of the building and the desire for more accurate wind loading and acceleration...
A Stochastic Source Spectrum for Engineering Application
The solution of a point source (double couple) combined with K. Aki/A. S. Papageorgiou's stochastic source model is used to establish the power spectrum at the acceleration...
Settlement of Light Buildings on Loose Sand
This paper reviews several cases of settlement of lightly loaded structures supported on granular soils. The concept of settlement ratio is presented. Measurements indicate that the settlement...
Structural Settlements at a Major Power Plant
The foundation design for the Intermountain Generating Station was based on comprehensive geotechnical investigations that included cone penetrometer tests, borings, pressuremeter tests,...
Large Scale Testing Facility for the Evaluation of Structural Systems Under Critical Loads
The Charles Lee Powell Structural Systems Laboratory at the University of California, San Diego, provides, with a 50 ft. high reaction strong wall and a 120 multiplied by 50 ft. box girder...
Experimental Studies, Structural Design and Full-Scale Measurements for the Columbia Seafirst Center
The Columbia Seafirst Center is a 76-story office tower located in downtown Seattle, Washington. It rises to a height of about 940 feet above ground and is the world's 10th...
Comparison of Predicted and Measured Dynamic Behavior of Allied Bank Plaza
Structural engineering aspects of a monitoring program to measure Allied Bank Plaza tower's dynamic response to wind are presented. In particular, field data developed during...
Design of Viscoelastic Dampers for Columbia Center Building
To reduce the dynamic response of a building with a given height and plan area to wind load, aside from inherent damping of the building, the designer has a few options available to him/her....
Return to search