Bridge Inspection by Dynamic Loading Technique
This paper describes, a case study of the evaluation of the structural integrity of a New York State Thruway bridge using the dynamic loading technique. The study was undertaken in a effort...

Standards for Pile Load Tests in Permafrost
A requirement exists to establish standard procedures for conducting pile load tests in permanently frozen soils. The methods outlined in the ASTM Standards for piles in thawed soils do...

Creep of a Strip Footing on Ice-Rich Permafrost
Creep settlement tests were performed on a strip footing founded on the surface of ice-rich aeolian silt permafrost. The tests consisted of applying four step loadings to a 10 in. (25....

Bentonitic Slurry in Constructing Drilled Piers
Bentonitic slurry is employed extensively in the construction of drilled shafts. While serious problems can occur, evidence is presented to show that the proper use of slurry will lead...

Installation of Category I Caissons
Founding a proposed safety-related Category I structure of a nuclear power plant on rock socketed caissons necessitated using precision installation techniques. These techniques were chosen...

Predicted and Measured Performance of a Foundation
The predicted and measured short term foundation behavior of a 28 story building in downtown San Antonio, Texas is reported. The soil is a stiff to hard clay and clay shale. The design...

Geotechnical Behavior of Underreams in Pleistocene Clay
Enlarged bases are often constructed in cylindrical drilled-and-cast-in-situ foundation elements (footings, bored piles) to increase their capacity. Enlarged bases that are cut mechanically...

Behavior of Drilled Piers in Layered Soils on Texas Barrier Islands
Twenty-eight full scale load tests and the results of 41 geotechnical studies were analyzed to correlate shear strength interpreted from field and laboratory test data with those derived...

Comparison of Caisson Load Tests on Chicago Hardpan
The results from two relatively recent instrumented caisson load tests from different sites on Chicago Hardpan are compared with a 'classic' large scale caisson...

Observations on Load Tests for Drilled Shafts
This paper focuses on three specific areas pertaining to load tests for drilled shafts: 1) basic considerations and load testing procedures, 2) interpretation of uplift load test information,...

Review of Repeated Axial Load Tests on Deep Foundations
A review of the literature is presented on the axial capacity of deep foundations subjected to repeated loads. Data are summarized on anchors, driven piles, and drilled shafts. In general,...

Vehicle Sound Power measurement Using the Acoustic Intensity Method
The use of the two microphone Acoustic Intensity Method of obtaining accurate measurement of over-all sound power of large wheel loaders is described. This system is in operation, within...

Strength of Composite Beams under Seismic Loading
Effective width of a concrete slab of a composite beam is specified in various specifications, but their theoretical backgrounds are obscure. Originally, they must have been specified...

Load-Carrying Capacity and Remaining Life of First-Built Composite Girder Bridge in Japan
Kanzaki Bridge, Osaka, Japan, was the first steel-concrete composite bridge built in 1953 to carry the Osaka Prefectural Road over Kanzaki River. The bridge was removed in 1978 after 25...

Dynamic-Fatigue Response of Continuous Composite Bridges
The dynamic response of continuous composite bridges and the influence of fatigue loading at resonance frequency on the structural response are investigated. It is shown that cracking...

The Eurocodes and Shrinkage in Composite Beams
The two parts of this paper relate to different aspects of design procedures for composite structures of steel and concrete. First, recent developments in the coordination of the eight...

Strength of Biaxially Loaded SRC Columns
The paper presents the results of an experimental study on the elasto-plastic behavior of 'Steel reinforced concrete (SRC)' columns subjected to biaxially eccentric...

Beam-to-Column Connection of a Composite Structure
Composite structures can exhibit excellent performance against seismic force, and fire safety as well. However, the traditional steel reinforced concrete (SRC) system or concrete encased...

Beam to Column Stress Transfer in Composite Structures
To clarify the mechanism of the stress transfer from the steel beam to the composite column through the beam-column joint, eight exterior beam column assemblies were tested under reversed...

Seismic Strengthening of Existing RC Buildings
Seismic strengthening of existing reinforced concrete (RC) frame buildings by the use of steel braces or panels was studied experimentally. A special joint between steel elements and the...

 

 

 

 

Return to search