Simplified Stress and Deformation Analysis for Pipeline Construction
This paper discusses the strength and deformation behavior of flexible steel pipes during pipeline construction. Some possible simple and quick solutions to these special design and construction...
Longitudinal Prestressed Piping for District Heating
The design of recently installed hot water district heating systems in the United States is based on similar systems developed in Europe. Longitudinal prestressing is used in the design...
Stress-Intensification Factor and Flexibility Factor in Seismic Analysis of Continuous Buried Pipelines
The topics of intensified stresses and increased flexibility in pipe bends subjected to bending loads are discussed in this paper. Also discussed are dynamic strain compatibility between...
Buried Fiberglass Pipe Response to Field Installation Methods
In 1970 near Yuma, Arizona, a field test installation of 30 inch diameter fiberglass pipe was constructed. Twelve years later the pipeline was remeasured. Measurements of pipe profile,...
Strains Induced by Combined Loading in Buried Pressurized Fiberglass Pipe
In 1983 Owens Corning Fiberglas and Utah State University collaborated on a study of combined strain behavior of fiberglass pipe to quantify the bending strain reduction as a function...
Long Term Testing of Centrifugally Cast Glass Fibre Reinforced Plastic Pipes (RIRP)
The paper discusses testing of pipe manufactured by centrifugal molding. The tests included external load tests, internal load, hydrostatic internal pressure, and cyclic internal pressure....
Buried Fiberglass Pipe Performance and Installation Requirements and Design Calculations in International Standardization
This paper elaborates on a proposed standard covering details of fiberglass pipe buried installation requirements and criteria for selection of pipe stiffness. It also discusses the selection...
Successful Use of Centrifugally Cast Glassfiber Reinforced Plastic (GRP) Pressure Pipes for Public Works in Sweden
Centrifugally cast GRP pipes were introduced in Sweden 17 years ago for industrial applications mainly as a gravity pipe. The process of pipe manufacturing as well as the pipe itself and...
Proportioning Reinforcement for Buried Concrete Pipe
The proportioning of reinforcement between inner and outer cages that is specified in ASTM Standard Specification C76 for concrete pipe in sewer and culvert applications is examined in...
A New Alternative in Steel Construction?Partially Restrained Connections
Lack of formal training in methods as well as the lack of specific guidelines have limited the understanding and utilization of semi-rigid connection technology. A renewed interest in...
The Effect of Connection Flexibility on Steel Members and Frame Stability
With the advent of Load and Resistance Factor Design (LRFD) and the many existing moment-rotation curves for connections, the use of actual connection flexibility in the design process...
Utilization of Experimentally Obtained Connection Data in Assessing the Performance of Steel Frames
Data from over 70 separate experimental studies on steel beam to column connections are reviewed with particular reference to the joint's in-plane moment-rotation characteristic. More...
Buckling of Flexibly-Joined Simple Frames
A nonlinear analysis of plane elastic frames is presented. The static loading consists of both eccentric concentrated loads (near the joints) and uniformly distributed loads on all or...
Behaviour and Strength of Steel Frames with Semi-Rigid Connections
A research study was started at the Politecnico of Milan (Italy) to investigate the influence of the main governing parameters on the behaviour and strength of flexible frames. A sophisticated...
Joint Flexibility in Steel Frames
This paper investigates the effects of connection flexibility and panel zone deformation on the behavior of plane steel frames. The incorporation of these factors in frame analysis will...
Flexibility of Steel Seismic Moment Connections
Relevant Berkeley experimental results are critically evaluated to determine the flexibility of W18 W24 beam joints with and without stiffeners and/or doubler plates. The paper discusses...
Research Needs for Extant Iron and Steel Buildings
A brief review of iron- and steel-making processes is background for the development of shapes and codes. Sources of information for the condition assessment of iron and steel buildings...
Structural Integrity Assessment of the Flexible 870 Advanced Design Bus
The Grumman Flxible 870, a lightweight advanced design urban bus, entered service in Atlanta, GA in 1978, and some 2,800 of these buses were in service nationwide by 1980. In the autumn...
Restoring the Capitol's West Front
After 25 years of debate, preservation (rather than extension) of the West Front of the U.S. Capitol building in Washington, D.C. has begun. A network of stainless steel rods is being...
Romanesque Reused
When Union Station in St. Louis, Mo. was built in the 1890s it was the world's largest railroad station. Having been abandoned by the railroads in the 1970s, it was reopened...