Excavation in Hard Clays of the Keuper Formation
For the construction of a lock on the Main-Danube-Canal in South Germany a 30 m deep cut had to be excavated in the overconsolidated clays and claystones of the Keuper formation. The strength...

Attaching Steel Members to Reinforced Concrete Elements
A variety of structural systems have been devised to strengthen existing buildings for improved seismic resistance. Strengthening methods currently in use for reinforced concrete structures...

Seismic Tests of Friction Damped Steel Frames
This paper presents the results obtained from qualification tests of a new friction damping system, which has been proposed in order to improve the response of Moment Resisting Frames...

Hysteretic Behavior of Composite Diaphragms
Floor systems constructed with steel-deck-reinforced concrete are described. When used to resist lateral loads these systems are referred to as diaphragms. A description of a test arrangement,...

Cyclic Energy Absorption by Reinforced Concrete
Results are presented on the basis of experiments conducted on conventional and steel fibrous reinforced concrete beams. The effects of the amount and nature of steel reinforcement and...

Building Records from 1984 Morgan Hill Earthquake
The dynamic response of 23 structures instrumented by the California Strong Motion Instrumentation Program was recorded during the magnitude 6. 2 (ML) Morgan Hill earthquake of 24 April...

Strengthening of a Multi-Story Building with Deflection Constraints
Occasionally the existing structural or nonstructural systems of a building being strengthened require the imposition of deflection constraints or limits in order to avoid an undesirable...

Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part I Gross Behavior
As a part of the U. S. -Japan Cooperative Research Program Utilizing Large-Scale Testing Facilities, a six-story, 2 by 2 bay, concentrically K-braced steel building was constructed in...

Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part II Local Behavior
The full-scale six-story concentrically K-braced steel building was subjected to Miyagi-Ken-Oki simulated earthquake whose peak intensity was 500gal. Local behavior of the test building...

Earthquake Response Simulation Capacity of Pseudo Dynamic Testing?Experimntal Demonstration and Analytic Evaluation
The response accuracy of the pseudo dynamic test was evaluated from the shake table and pseudo dynamic tests conducted for a two story steel braced frame model. The obtained responses...

Flexural Behavior of Reinforced Masonry Walls and Beams
Many reinforced masonry walls and beams were tested as a part of the U. S. -Japan cooperative research program on masonry building structures. Six concrete block and two clay brick masonry...

Full Scale Tests of Cladding Components
A full scale, six story, steel frame at the Building Research Institute, Tsukuba, Japan was constructed for a series of projects in the U. S. -Japan Cooperative Research Program. This...

System Identification Applied to Pseudo-Dynamic Test Data: A Treatment of Experimental Errors
A single-input single-output system identification technique, used to estimate the modal properties of a full-scale six-story steel structure tested within its elastic range by the pseudo-dynamic...

Comparative Seismic Response of Damped Braced Frames
The behaviours of braced steel building frames with friction joints and with eccentric bracing, under seismic forces, are compared. Nonlinear time history dynamic analysis is used. Friction...

Interaction Effects in Vertically Excited Steel Tanks
Following a brief review of the hydrodynamic effects induced by a vertical component of ground shaking in liquid-filled, circular, cylindrical, steel tanks that are rigidly supported at...

Cladding Design for Tall Buildings
In the past twenty years, glass cladding has emerged as a popular and economic building material. Its use in tall buildings which are constructed in high-risk wind and seismic geographical...

It's Only Visual Inspection (Welding Inspection)
Unless specified otherwise in the Contract Documents, Visual Inspection will be performed on all fabrication/erection welding for projects that utilize the Specifications for the Design,...

Damping in Tall Buildings: Its Variability and Treatment in Design
Increasingly, damping is being recognized as an important factor in the design of structures. It is at the same time a property which is relatively poorly defined, more acquired than engineered...

Damping Systems to Limit the Motion of Tall Buildings
Two types of damping systems have been used successfully in building applications - the Tuned Mass Damper, and Viscoelastic Damping Units. In the past, Tuned Mass Dampers were used in...

Design of Viscoelastic Dampers for Columbia Center Building
To reduce the dynamic response of a building with a given height and plan area to wind load, aside from inherent damping of the building, the designer has a few options available to him/her....

 

 

 

 

Return to search