The Use of SCADA for Real-time Calculation and Monitoring for CT Compliance at the Ralph D. Bollman Water Treatment Plant
The contra Costa Water District (CCWD) of Concord, CA was formed in 1935 under the authority of the State Water Code. CCWD purchases its water supply from the Central Valley Project (CVP),...
Vertical and Horizontal Deformations for Foundations on Sand: An Experimental Study
A natural scale model is used in order to investigate experimentally the sand soil deformation behavior which accepts loads by shallow foundations. The vertical and horizontal soil displacements...
Uplift Load-Displacement Behavior of Grillage Foundations
Full-scale field tests were conducted on steel grillage foundations for lattice transmission line towers that had been in place since 1929, 1947, and 1958. A total of eight tests were...
Replacement of a Failed Embankment Designed to Accommodate Large Settlement: A Case Study
Thick deposits of soft, normally to slightly preconsolidated, organic clay are common at low elevations along the riverbanks of southeast Texas. Both the moisture content and liquid limit...
A Case History of Settlement of an Embankment on Lagoonal Deposits Influenced by Artesian Conditions
A geotechnical engineering investigation was performed for the Pearl Kai Center, a shopping center in the Pearl Harbor area of the island of Oahu, Hawaii. The proposed commercial development...
Towards a Rational Method of Predicting Settlements of Spread Footings on Sand
Prediction of settlements of both large and small spread footings on sand has traditionally been carried out using methods which are largely empirical. In recent years, advances have been...
An Alternative Formulation of Volume-change Behavior of Soils
The traditional approach based on the semi-logarithmic representation of volume change data is known to work relatively well for prediction of ground settlements. This approach has been...
Cyclic Loading for the Measuring of Soil Consolidation Parameters
A method of determination of soil consolidation characteristics using sinusoidal loading is described. It can be performed in laboratory test or in situ observation as well, with different...
Prediction of Low Level Vibration Induced Settlement
A prediction model of vibration induced settlement was developed for small to intermediate vibration levels (0.25-1.78 cm/s). Seven factors affecting vibration induced settlement such...
Settlement Predictions Using Piezocone
Detailed data on settlement predictions and measured values are given for two water tanks and an area of fill constructed on a thick soft clay stratum that showed decreasing preconsolidation...
Performance of a Steel Tank Founded on a Marine Clay
For tanks on soft clays, the soil is often preloaded before tank construction to increase bearing capacity and minimize post-construction settlement. In the case history described here,...
Settlement of Deep Compacted Fills in California
Measured settlement of deep compacted engineered fills from a single site were summarized and compared to data from other sites. The data indicate that the rate and magnitude of movement...
Compaction Grouting Stops Settlement of an Operating Water Treatment Plant
In early 1978, about a month into full-time operation, the new filter plant building for the water treatment plant for the City of Glenwood Springs, Colorado, experienced distress due...
Compressibility for Sand Under One-Dimensional Loading Condition
Empirical equations for one dimensional compression of sand do not include parameters characterizing properties of sand grains (e.g. moduli, size and shape of sand grains, and friction...
Application of the Diflupress L.D. Field Test to Settlement Calculation
Electricite de France developed a new in situ measurement apparatus (Diflupress L.D.) in order to predict the delayed settlements that can appear under heavy constructions. From the experimental...
Collapse Mechanism of Compacted Clayey and Silty Sands
The mechanism of wetting-induced collapse (hydrocompression) and the influence of fines ratios on compacted sandy soils are investigated. Various ratios of clay and silt are mixed with...
Settlement of Building Foundations on Clay Soil Caused by Evapotranspiration
This paper reports on the results of a field investigation and settlement monitoring program which involves five buildings founded on shallow foundations in the sensitive clay deposits...
The Behavior of a Building with Shallow Foundations on a Stiff Lateritic Clay
The use of shallow foundations for buildings in Sao Paulo, either on soils of the Tertiary Sedimentary Basin of Sao Paulo (TSBSP) or on those of saprolitic origin is not as frequent as...
Residual Soil Settlment Related to the Weathering Profile
Residual soils are the in-place residue from rock weathering. They differ greatly from the better understood deposited soils in that their particle arrangements and mineralogy reflect...
Stress-Deformation Behavior of an Embankment on Boston Blue Clay
An 11 m high I-95 embankment was thoroughly instrumented with piezometers, settlement rods and inclinometers to measure the behavior of the underlying 40 m thick deposit of Boston Blue...
Return to search