Comprehensive Rehabilitation Results From Stege Sanitary District
Seven sewer agencies, including Stege Sanitary District, in the East Bay of the San Francisco Bay Area embarked on a 20-year capital improvement program in 1987. The 300 million construction...
Simple Furrow Advance Ratio Evaluation Technique for Upgrading Management
A simple procedure using the Advance Ratio (AR) is presented. It utilizes on-farm gathered information of advance time, water application time, and depth applied for furrow irrigated field....
Evaluation of Infiltration Equations Used in Surface Irrigation
Computer simulations of an irrigation event were conducted using 6 full hydrodynamic models. All 6 models used the same surface flow equations and a different infiltration component. The...
Hydraulic Studies of Surface Drainage from Level Furrows
Field studies have been completed to quantify the surface drainage phenomenon from level furrows which were rapidly flooded and then drained from the inlet end of the furrow. The proportion...
Furrow Irrigation Performance Using Real Time Control
Computer simulations were conducted, using a simple feedback control algorithm, to determine the potential for improvement of irrigation performance using real-time feedback control. Field...
Surface Water-Groundwater Relations for Open Channels
For losing channels with clean wetted perimeters (no clogging layers), the seepage rate varies essentially linearly with depth to groundwater if the groundwater is relatively shallow,...
Simulation of Contaminant Transport Using NMOL Technique
In this paper, a new numerical method, called Numerical Method of Lines (NMOL), is used to solve initial-boundary value problems for solute transport in soils. The simulation results are...
Proposed Improvements in Lateral Canal Operations
Uniform and flexible supplies of irrigation water are required for farmers to make the best use of their on-farm application systems. Results of a study of deliveries at the lateral canal...
Random Characteristics of Sediment-Laden Flows and the Techniques of Effective Sediment Exclusion on Dujiangyan Irrigation Project in China
The irrigation system is over 2,200 years old and discharges water at a rate of 340-740 m3/s from the Minjiang River. The average slope of the river...
Ultrasonic Flow Meter Testing
Six ultrasonic flow meters were tested in a hydraulics laboratory. Accuracies better than 2% were obtained with two transit-time meters on 14 inch diameter steel tubing. Poorer accuracies...
Visual Estimates of Flume and Weir Operating Conditions
Laboratory studies were conducted on a rectangular broad-crested weir to determine the effects of entrance and exit conditions on the prediction of discharge and required energy loss....
Achieving Accurate Irrigation Water Measurements with Propeller Meters
Propeller meters are now being used extensively to help quantify and manage the huge but poorly distributed water supplies available to irrigated agriculture in the western states. Careful...
Adjustment of Mountain Stream Channels to Flow Regime Alteration, Preliminary Analysis
One aspect of instream flow regimes being actively debated is the need for channel maintenance of flushing flows. However, little quantitative information exists as to how different types...
Instream fFlows for the Big Bend Reach of the Platte River
The Big Bend reach of the Platte River in Central Nebraska provides habitat for 230 species of migratory birds. Included are six endangered or threatened species and the world's...
Stable and Environmental Channel Design
The Wildcat and San Pablo Creeks Flood Control Project is located in Richmond, California. Both streams flow through a highly urbanized area, periodically overflowing their banks and causing...
Computer Aided Hydraulic Design of Open Channels
Over a 10 year period, the computer program, WASURO, was developed by the U.S. Army Corps of Engineers District, Los Angeles (LAD), which utilized many of the criteria of the previously...
Power Formula for Open-Channel Flow Resistance
This paper evaluates various power formulas for flow resistance in open channels. Unlike the logarithmic resistance equation that can be theoretically derived either from Prandtl's...
Flow Measurement Using a Digital Pressure-Time Method
This paper describes flow measurements performed by TVA's Engineering Laboratory as a part of absolute efficiency measurements of the two units at the Great Falls Hydro Plant....
Closed-Loop Control for Hydraulic Laboratory Operation
The implementation of Closed-Loop Feedback Control in the Bureau of Reclamation's Hydraulic Laboratory flow delivery system has provided an important new modeling tool for...
Instrumentation for a Dry-Pond Detention Study
A 12.3-acre, fully urbanized, residential land-use catchment was instrumented by the U. S. Geological Survey in Topeka, Kansas. Hydraulic instrumentation for flow measurement includes...
Return to search