Architectural Configurations in Vina del Mar
This paper identifies the architectural characteristics of 121 reinforced concrete buildings in Vina del Mar. These characteristics are related to the damage statistics for the building...

Ductility and Failure Characteristics of Concrete and Rock Subjected to Complex Load Paths
Strength, ductility and the complex material response features of concrete and rock should be evaluated through carefully planned material properties test programs designed to subject...

Implications for Limit State Design of Inverted V Braced Steel Structures
Inverted V braced steel structures with backup ductile moment-resisting frames forming a dual system, exhibit complex inelastic behavior under severe seismic excitations. Thus, current...

Building Frames Subjected to 2D Earthquake Motion
Inelastic response of a simplified model of a 10-storey building frame was analyzed to assess the effects of bi-directional seismic loading. Interaction between the strengths in the two...

Seismic Load Effects on a Scaled Model Structure
A long term observation on a scaled steel braced frame model with intentionally reduced seismic strength is ongoing since 1983. This paper examines the seismic load effects of two earthquakes...

Detection of Seismic Structural Damage
Damage analysis models based on equivalent modal parameters are used to identify the serviceability limit state for structures subjected to earthquake loads. A model for the analysis of...

A Damage Model for Reinforced Concrete
The damage index developed by the authors models concrete damage as a low-cycle fatigue phenomenon. By quantifying the energy dissipated as a fraction of the total energy dissipation capacity,...

Biaxial Damage Assessment
The structural system under investigation is a frame subject to seismic excitations. The analysis accounts for the spatial distribution of beams, columns and bracing system. It also considers...

Seismic Isolation of the USC University Hospital
This paper provides an overview of the various structural engineering tasks that are associated with the implementation of the design of a seismically isolated structure. The project is...

Seismic Isolation for the Los Angeles County Fire Command and Control Facility
The use of seismic isolation is becoming an increasingly important consideration in improving the earthquake lifelines of a community. This paper identifies the major problems encountered...

The Application of Seismic Isolation to Bridges
Unlike a building application the primary intent in a bridge is to protect the structure below the plane of isolation - the superstructure being relatively rigid to in-plane loads and...

Development of Design Requirements for Seismically Isolated Structures
This paper provides background and describes on-going work by the Structural Engineers Association of California (SEAOC) to develop design requirements for seismically isolated structures....

Seismic Strengthening of a Historic Unreinforced Masonry Building
The building involved is a four-story unreinforced masonry structure. Considerations related to development of design criteria are presented along with retrofitting strategies. The building...

1988 Provisions for Masonry Design
The 1988 Uniform Building Code has seen a significant change in the seismic design requirements, Chapter 23, for the design of structures subjected to earthquake loads. This paper discusses...

Development of Inelastic Reduction Factors to Provide an Elastic Design Procedure
R factor values can only be rationally selected when they are based on in part nonlinear inelastic dynamic analyses of building system types. However, it is informative to discuss the...

Recent Developments in Testing Base Isolation Systems
One of these developments has been the ability to test large scale isolation systems using simulated seismic loads. These tests have not only proven the performance and reliability of...

Seismic Isolation of Nuclear Plants: A World Overview
The French were first to apply seismic isolation to the design of nuclear structures. Two large Pressurized Water Reactor plants (PWR) were isolated; the two unit Koeberg station in South...

Response of Concrete Buildings to Lateral Forces
ACI-ASCE Committee 442 (Response of Concrete Buildings to Lateral Forces) has just issued its report (ACI-ASCE 442 1988a). In that Report, the performance of reinforced concrete buildings...

Inelastic Seismic Design of Concrete Structures
This paper provides an overview of the state-of-the-art publication on the same subject under preparation by ASCE-ACI Committee 442's Ad Hoc Subcommittee on Inelastic Response...

Deformability of Reinforced Concrete Members
A large volume of test data has been evaluated to establish deformability of reinforced concrete beams, columns, and structural walls in the inelastic range. Experimentally observed deformation...

 

 

 

 