The Reliability of Treatment Systems
The purpose of this paper is to present the results of case studies of zero and first order reactor systems and an activated sludge treatment system consisting of a primary settling tank...

Seismic Interaction Among Numerous Masses Founded on a Viscoelastic Stratum
The steady-state harmonic response of systems comprising numerous masses resting on a homogeneous, viscoelastic stratum with hysteretic damping is studied. The stratum, bearing on a rigid...

Single Point Moorings for the Bering Sea
Multi or single-legged buoy systems such as conventional CALMs or SALMs would not survive the winter season in the Bering Sea because the forces generated in the anchoring chains by pack-ice...

Arctic Foundation Selection: A Decision Matrix
An idealized matrix diagram is presented of the decision making process involved in determing an economic Arctic foundation type that is best suited to the proposed above-grade structure....

Hammering Out a New RCRA
Recent amendments to the Resource Conservation and Recovery Act (RCRA) add thousands of new waste generators and many new wastes to the list of those to be regulated. Some say RCRA is...

Modeling a Water Distribution System
Problems encountered in modeling the water distribution system for the City of Norwich, NY are discussed and the procedures used to solve each problem are described. The interpretation...

Complications in the Design and Analysis of Small Water Distribution Systems
The design and operation of small treatment and distribution networks can sometimes be more complicated than the design of large metropolitan systems. More often than not, the use of standard...

Modelling Complex Water Distribution Systems
A program previously used for the analysis of hundreds of water distribution systems was successfully modified to provide the features needed for the extended simulation of large complex...

Practical Optimization of Looped Water Systems
This paper describes one tool that might be part of a package to assist a design engineer in sizing pipes, determining ideal locations for booster pumps and their heads, determining heads...

Understanding Secondary Clarifier Behavior
The author has developed a graphic procedure for analyzing the hydraulic behavior of settling tanks. Data have been used in numerous cases to devise low cost in-tank and external improvements...

Retrofitting Lifeline Facilities: The Japanese Approach
A brief history of the prediction of a major earthquake in the Tokai Area of Japan is reviewed. Planning and mitigation incorporating all levels of government and the private sector is...

Dynamic Response Correlation of Cylindrical Tanks
The May 1983 Coalinga Earthquake provided an opportunity to correlate earthquake performance of cylindrical liquid storage tanks with behavior observed in laboratory shaking table experiments....

Caisson
The Jamaica Bay Water Pollution Plant was renovated and upgraded from l973-l983 and included sinking a 116 ft. x 105 ft. caisson 50 ft. deep adjacent to city streets and buildings. The...

Transient Fluid-Structure Interaction of a Cylindrical Tank with a Flexible Baseplate
Analytically predicted coupled natural frequencies, response functions, and transient responses are compared with measured values for a partially filled cylindrical tank subject to excitation...

Alternative Layouts for Hydro Headrace Tunnels
The recent development of tunnel boring machines capable of excavating hard rock at virtually any grade together with the Norwegian experience in compressed air surge tanks provides the...

Walden Hydroelectric Power Project
The Wallkill River at Walden, New York, produced hydroelectric power from 1909 to 1966. Using turbines dating back to the original hydroelectric development, the Walden hydroelectric station...

Guidelines for the Seismic Design of Oil and Gas Pipeline Systems
Current knowledge on the practice of earthquake engineering for oil and gas pipeline systems is presented. Such systems typically consist of buried oil, gas, or product pipelines and aboveground...

A Standard for the Measurement of Oxygen Transfer in Clean Water
This standard was developed to measure the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water. The standard is applicable to laboratory scale oxygenation...

Thermal Storage, Now and Future
Two-part article describes a 250 x 82 x 22 ft underground concrete tank that stores about 29,000 ton-hours of cooling effect for Yale University's medical school complex....

An Improved Design for Grain Storage Tanks Solves Problem of Brittle Failures
The welded tank features fracture-tough steel and tube stiffeners to overcome problems evident in several failures of major tanks in recent years. Used extensively for grain storage in...

 

 

 

 

Return to search