Elevated Water Tank Inelastic Seismic Analysis
In 1988, the Seattle Water Department hired CYGNA, a consulting firm, to assess the seismic reliability of their water system, since major earthquakes can occur in the area. Their study...

Simplified Uplift Analysis of Unanchored Cylindrical Tanks
Seismic tank damage has been reported in almost every major earthquake in the past, sometimes with serious environmental ramifications, thus raising concerns about the safety of these...

Performance of Liquid Storage Tanks during the 1989 Loma Prieta Earthquake
Utilities and industrial facilities in the strong shaking area of the 1989 Loma Prieta earthquake include a large inventory of tanks of all types. The earthquake induced a few incidents...

Towards Reduction of the Vulnerability of Multi-Tank Storage Facilities
Accident scenarios in large scale industrial plants show that conventionally designed multi-tank storage facilities are susceptible to domino effects. With the aim to reduce the probability...

Column Separation in Pumped Pipelines
Pressure transients are common occurrences in water supply systems. Pipeline standards and design/testing techniques will normally provide sufficient protection for transmission and distribution...

Keeping Lifelines Alive
There were no city water supplies to fight the fires in San Francisco after last year's earthquake. The fires were brought under control because of an historic auxiliary water...

Programmatic Challenges and the Value of Testing on the West Valley Demonstration Project's Vitrification Facility Design
The primary objective of the West Valley Demonstration Project (WVDP) is the solidification of approximately 2.1 million liters (560 thousand gallons) of high-level waste (HLW) which resulted...

Soluble High-Level Waste Decontamination and Disposal at the Savannah River Site
The high-level radioactive waste that has accumulated at the Savannah River Site is stored in large underground steel tanks. Programs to remove the soluble waste from the storage tanks,...

Post-MECO Propulsion System Requirements for Placement of an STS External Tank in Low Earth Orbit
This paper discusses the findings of a series of computer simulations carried out at the National Institute of Standards and Technology to investigate the requirements for powered flight...

A Methodology for Optimal Control of Pump Stations
Pumping water to utility customers is an expensive service which consumes large amounts of energy. Most approaches to date require simplifications and assumptions for the specific system...

Effects of Tide on Variation of Beach Profile
Effects of tide on variation of beach profile are examined experimentally. It is clarified that tidal effect appears differently when it acts on beach of different profiles. Namely, in...

Design of Fiberglass Reinforced Plastic Underground Storage Tanks
The purpose of this paper is to discuss the design and construction techniques of fiberglass composite underground storage tanks. The scope of this paper is limited to the straight shell...

Let the Buyer Beware
As recently as the 1970s, state highway agencies blindly purchased land for projects without much concern for hazardous waste. But that changed in 1980 with Superfund legislation, specifically...

U.S. Tackles Leaking Tanks
Regulations to deal with leaking underground storage tanks have been in force since 1984 and deadlines for compliance began in 1989 for tanks installed before 1969. The Environmental Protection...

Seismic Design of Liquid Storage Tanks
Originally published in: Journal of the Technical Councils, ASCE, TC1, April 1981...

Vibration Control Damper Using Sloshing of Water
The objective of this study is to develop a method of reducing wind-induced vibration of long-period structures utilizing sloshing of water in tanks added to the upper part of the structures....

Seismic Isolation of Storage Tanks
There has been a significant amount of research activity over the past decade on the seismic design of storage tanks. The seismic design issues and limit states are quite complex due to...

Seismic Large Amplitude Liquid Sloshing?Theory
The sloshing phenomenon in seismically-excited, rectangular, liquid storage tanks is addressed. In particular, a semi-analytical method to study the effects of large amplitude sloshing...

Buckling Criteria for Earthquake-Induced Overturning Stresses in Cylindrical Liquid Storage Tanks
Perhaps one of the most common forms of seismic damage to cylindrical liquid storage tanks made out of steel is buckling of the tank wall due to vertical overturning stresses. Buckling...

Big-Scaled Tilt Test on Uplifting Behavior of Oil Storage Tanks
The authors conducted a series of static tilt tests using a very big model with the full similitude in order to investigate the uplifting behavior of large-scaled tanks. The model was...

 

 

 

 

Return to search