Evaluation of Wood Floor Vibration Design Criteria
In the United States, floors in wood buildings are designed according to strength and deflection criteria under static uniform loads. With the introduction of engineered joist products...
The Use of Coda Waves for Characterizing the Site Effect on Strong Ground Motion
The well established separability of source, path and site effects on coda waves of local seismic events offers the most effective means for determining the site amplification factor empirically....
Lateral Load Resisting Systems for Circular Buildings
The design of structural systems to economically limit inter-story drift and building acceleration for circular high rise buildings is presented within the framework of two recently constructed...
Construction of the Baytown Bridge, Houston
Connecting Baytown and LaPorte, the Baytown Bridge is a twin structure with four traffic lanes each. Its structure is designed as a cable-stayed bridge with concrete towers and composite...
Construction of the Clark Cable-Stayed Bridge at Alton, Illinois
The Clark Cable-Stayed Bridge crosses the Mississippi River at Alton, Illinois. The successful bid by McCarthy Bros/Clark Bridge JV was for the steel alternative. The bridge design included...
Wind Studies of the Owensboro Bridge, Kentucky
Wind tunnel studies on the Owensboro Bridge are described in this paper, including 1:50 scale sectional model tests and 1:160 scale aeroelastic model tests. Comparisons are presented and...
Timber Pile Length Determination Using a Nondestructive Technique
Determining timber pile length is critical when evaluating the potential effects of scour and for determining pile capacity. Unfortunately, records of timber pile lengths are typically...
Seismic Fragility Analysis of Sheahan Pumping Building
This paper presents a seismic fragility analysis of the Sheahan pumping building located in Memphis, Tennessee. In the analysis, seismic response is determined from the response spectrum...
Earthquake Barrier Technology: Sliding-Friction Energy Dissipation
The first project in America to use friction damping was approved by the City of Los Angeles for the retrofit of a 10-story concrete frame building, designed to resist a Maximum Credible...
Seismic Response and Retrofitting of Non-Ductile Reinforced Concrete Bridges
The Interstate I5/I605 Separator in Los Angeles County was severely damaged during the October, 1 1987 Whittier Narrows Earthquake. This damage included non-ductile shear failure in the...
Aesthetic Considerations in the Design of a Stack Extension
The Connecticut D.E.P. mandated increase in height of the boiler stack at Backus Hospital in Norwich, CT presented many problems. Adding a new 45 foot vertical section atop the old brick...
Implementation of Passive Energy Dissipation Systems in the United States
Significant advances in the field of passive energy dissipation for improved structural seismic resistance have been made in recent years. Developments in research and analysis techniques...
Utilizing Visco-Elastic Dampers in the Seismic Retrofit of a Thirteen Story Steel Framed Building
A 13 story steel framed building in Santa Clara Country, California exhibited strong beating effects (torsional coupling) and prolonged building response as result of various seismic events....
Design and Field Performance of a Metal-Plate-Connected Wood Truss Bridge
This paper describes an on-going study on the design and performance attributes of an experimental wood-truss bridge. This is believed to be the first roadway bridge application of metal-plate-connected...
Acoustic Emission Monitoring of Steel Bridges
Global nondestructive monitoring techniques are of great significance for rapid monitoring of bridges. One promising technique involves monitoring the microseismic events (Acoustic Emissions,...
Long-Term Monitoring of Civil Structures using Smart Structures Techniques
A smart monitoring program for a hybrid concrete-steel building in Washington, D.C. has been developed. The building is currently being instrumented with a variety of strain and corrosion...
Seismic Response of Concrete Tilt-Up Systems
A Summary of the measured dynamic response of a one-story, till-up warehouse located in Hillister, California, is presented. Acceleration and relative displacement histories may be used...
Seismic Behavior of Non-Ductile Concrete Frame Structures
Non-ductile reinforced concrete (RC) frame structures designed and constructed during the 1950's through 1970's exist in many regions of the United States. The frames of these structures...
Design and Analysis of the 712 Fifth Avenue Structure
New York City's 712 Fifth Avenue is an extremely-slender concrete tube tower. This text addresses the structure's lateral structural system, wind analysis, computer model, thermal analysis...
The Structural History of the Jacob Bachmann Tavern
The Jacob Bachmann Tavern is located in Easton, Pennsylvania. It is a collection of four interconnected buildings that have been constructed and modified over a period of 240 years. Structural...
Return to search