A Probabilistic Approach to the Response of Tall Buildings to Wind Loadings
Tall buildings constructed in recent years are light in weight, flexible and low in damping. This is the consequence of using lighter material with higher strength, and fewer interior...
Gust Speeds in Hurricanes
Based on strip-chart records of wind speeds representing 11 recording stations and four hurricanes, it is concluded that gust factors for hurricanes generally exceed the gust factors proposed...
Seismic Retrofit of R/C Columns with Inadequate Lap Splices
This paper presents experimental results on the use of rectangular steel jackets to improve the seismic performance of rectangular steel jackets to improve the seismic performance of rectangular...
Compressive Strength of Large Scale HSLA-80 Steel Cellular Sections of a Double Hull Ship Structure
An analytical and experimental large scale test program was conducted to investigate the instability failure modes of cellular double hull box sections. The main emphasis of the study...
Lateral Response of Unreinforced Masonry Infill Frame Panels
This paper presents the results of the out-of-plane testing phase of the National Science Foundation Grant BCS 9102347. This project addresses the out-of-plane response to lateral loading...
Optimization for Earthquake Loads
Structural optimization for seismic loads can be approached from a deterministic or nondeterministic point of view. Deterministically, the major difference between optimization of statically...
The Daytona Beach Large Wave Event of 3 July 1992
The fundamental mechanisms behind the anomalous large wave which struck Daytona Beach on 3 July 1992 are addressed. Although the wave was originally believed to have resulted from a submarine...
The Significance of Hydrodynamic Forces in Coastal Embankment Design
The dynamic forces of sea water and backfill soil acting on coastal embankment are analyzed by using a new finite-difference method. The Euler's equation and continuity equation are used...
Modeling Municipal Water Demands for a Pump Station Area
The Chasewood Pump Station/Residential Area in southwest Houston was selected for a detailed analysis of ground and surface storage water pumping by a University of Houston and City of...
Effects of Lateral Heading Flow Steadiness on Lateral Spillage
Hourly inflow and spillage rates from three lateral canals in the Imperial Irrigation District in Southern California were measured for seven months and subsequently analyzed to identify...
Designing Optimal Reliable Multiquality Water Supply Systems
A methodology which integrates optimal design and reliability of a multiquality water supply system is presented and demonstrated. The system constructed is able to sustain prescribed...
Improved Computer Simulation of 3D Wind Flow Around a Building
A two-layer method combining the k-? model with the one-equation model near the wall has been tested in computing the wind conditions around a cubic building. In contrast with the simple...
A Computational Algorithm for Analysis of Rectangular Footings Under Partial Contact with Soil
This paper describes a method to determine the distribution of base pressures under a rectangular footing experiencing partial contact of the footing with soil. Assuming the footing to...
A Technique to Perform Coupled Consolidation Analysis Using Two Independent Softwares
The consolidation of soils involves two interdependent processes. These are fluid (air and water) flows and the deformation of the soil structure. The two processes tend to be treated...
Computer Analysis of Lateral Loading in Wood-Framed Structures
Building codes and design techniques associated with single-family housing need to incorporate advances in architecture and construction so that the traditional life-safety building codes...
Footing Load Tests on Sand
Four full size footings were load tested at a site in Texas. The embedded footings were situated on a thin layer of stiff clay underlain by a thick deposit of medium dense to dense sand....
Uplift Load-Displacement Behavior of Grillage Foundations
Full-scale field tests were conducted on steel grillage foundations for lattice transmission line towers that had been in place since 1929, 1947, and 1958. A total of eight tests were...
Model Tests on Caissons
Laboratory tests were conducted on model caissons to better understand the settlement/deflection behavior of open ended caissons on sandy soil, with embedment depth, caisson diameter,...
Analysis of the Juturnaiba Embankment Dam Built on an Organic Soft Clay
The Juturnaiba Dam, located in the northern part of Rio de Janeiro State, Brazil, has 1.2 km of its length built on an organic soft clay about four meters deep. The construction of the...
A Case History of Settlement of an Embankment on Lagoonal Deposits Influenced by Artesian Conditions
A geotechnical engineering investigation was performed for the Pearl Kai Center, a shopping center in the Pearl Harbor area of the island of Oahu, Hawaii. The proposed commercial development...
Return to search