Optimal Distribution of Tuned Mass Dampers in Wind-Sensitive Structures
Modern high-rise buildings are susceptible to excessive accelerations at the upper floors in wind storms due to flexibility and low damping. In order to keep acceleration levels below...

Earthquake Energy Partitioning in Base Isolated and Dynamically Damped Structures
New earthquake energy spectra are proposed for practical design procedures using energy concepts. The spectra show integrated earthquake input energy of a unit mass with given natural...

Space Construction: A CSI Perspective
This paper outlines the control structure interaction (CSI) problem for space construction engineers. An overview of the Control Astrophysics and Structures Experiment in Space (CASES)...

Taming Structural Vibrations
Vibration is a common problem in buildings that contain large spaces and long spans, especially gymnasiums and dance studios. Research shows that people respond more adversely to continuous...

Floor Vibrations ? Tips for Designers
The purpose of this paper is to suggest a number of practical concepts which can be used to improve the performance of floor systems subject to occupant induced motion from either walking,...

Composite Floor Vibrations: Predicted and Measured
Several steel composite floor systems of relatively long span trusses for a number of high rise structures in the Chicago area have been subjected to field measurements to evaluate their...

Analysis and the Design of Multi-Layer Viscoelastic (V.E.) Dampers for Tall Structures
Vibrational motion of tall buildings can be damped by employment of viscoelastic passive dampers in the structure. The type of dampers selected depend on locations where relative displacements,...

Tuned Liquid Damper and Its Application to Tower-Like Structures
A new kind of damper, Tuned Liquid Damper (TLD) relying upon motion of, shallow liquid in a rigid container for absorbing and dissipating the vibrations energy is explained. The performance...

Full-Scale Measurement on Chiba Port Tower
Chiba Port Tower is a tall tower, 125m high, with a rhombus shaped plan. All of the surfaces are covered with half mirror glass. On the top of the tower, a 'Tuned Mass Damper'...

Vibration-Induced Wind Pressure on Large Span Flat Roof
Vibration-induced wind pressures on a large span flat roof was investigated by a wind tunnel using a uniformly turbulent flow. Measurements of pressures were made on an asymmetrically...

Vibration Control Damper Using Sloshing of Water
The objective of this study is to develop a method of reducing wind-induced vibration of long-period structures utilizing sloshing of water in tanks added to the upper part of the structures....

Experimental Study on Structural Control for Seismic Loads Using Passive and Active Devices
The feasibility of controlling the responses of structures against seismic loads is investigated through some experiments and numerical analyses for both the passive and active control...

Consequences and Achievement of Supplemental Damping for Improved Seismic Performance
An earthquake resistant design philosophy which relies upon increased stiffness and damping rather than increased strength and ductility has been investigated. The effect of adding supplemental...

Friction-Dampers for Economic Seismic Design
A novel structural system, which combines the strength and stiffness of a braced frame and energy dissipation capacity of the friction-dampers, has been used in the design of a reinforced...

Characteristics of a Structure-Foundation System
The dynamic characteristics of the structure-foundation system of a 1/4 -scale nuclear power plant containment model is studied using seismic records. The model structure is treated as...

Random Vibration of a Discrete-Distributed System
The stationary response of an arbitrarily complex, classically damped discrete-distributed system subjected to stationary Gaussian white noise is derived. For certain excitations, the...

On Response Spectrum Approach for Nonclassically Damped Structural System
A response spectrum approach to approximate the maximum response of nonclassically damped structural systems is presented. The maximum response is expressed in terms of the sine spectrum,...

A Modal Coupling Procedure for Structural Dynamics
A method is presented for synthesizing the real modes of substructures to obtain the complex modes of the combined structure. These complex modes properly include the nonclassical damping...

Seismic Response of Simple Structures with Coulomb Damping
A single story structure incorporating a floor-sliding mechanism for dissipation of vibration energy through Coulomb friction damping is examined. The response of this structure is evaluated...

Prediction and Measurement of Wind Response: Case Story of a Wind Sensitive Building
The wind-induced horizontal accelerations of a 43 story office tower in New York City were monitored during 11 occasions over a period of about six months. The building dates back to the...

 

 

 

 