Fatigue of a Steel Plate and Concrete Composite Bridge Deck by Moving Loads
This paper is devoted to reveal fatigue characteristics of a steel plate and concrete composite bridge deck, which is often called the Robinson slabs, subjected to vehicle loads. 16 model...

Proposal on Story Drift Limit Based on Axial Behavior of Column under Seismic Loads
The main function of columns primarily is to support axial loads both under and after repeated lateral loading from earthquakes. A definition of the story drift limit in any structural...

Behavior of Concrete-Filled Steel Tubular Three-Dimensional Subassemblages
Three-dimensional subassemblages consisting of a concrete-filled steel tubular column and four H-shaped beams were tested under a constant axial load on the column, constant beam loads...

Application and Recent Development of a Numerical Model for Composite Beams with Partial Shear Connection
This paper deals with numeric analysis of composite steel and concrete beams for loads up to the ultimate beam capacity. Two versions of a numerical model are presented addressing such...

Influence on Steel Deck on Composite Beam Strength
Results of a recent study were described in which 7 push-out tests and 4 composite beam tests were conducted. The results were consistent with other recent studies reported in the literature,...

Composite Beams with Headed Studs in Narrow Ribbed Metal Deck
This paper presents the results of sixteen push-out tests conducted to study the behavior of headed stud connectors in composite beams with narrow ribbed metal deck placed parallel to...

Composite Walling
This paper describes a study into a system of walling that comprises two skins of profiled steel sheeting infilled with concrete. During construction the steel sheeting acts as permanent...

Numerical Analysis of Composite Slab Behavior
A new calculation procedure is described which provides an alternative to full-scale testing for composite slabs with ribbed decking used in buildings. This procedure consists of combining...

The Definition of a Short Composite Column
A `short' column in composite construction is defined as one which can be designed for its cross-section strength alone without the need to consider stability effects. An extensive study...

Strength Deterioration Behavior of Concrete-Filled Steel Tubular Beam-Columns
Cantilever beam-columns of steel square hollow section with or without filled-concrete were tested under constant axial load and alternately repeated horizontal load to investigate the...

Force Transfer in Composite Columns
The force transfer from steel to concrete without mechanical transfer devices in composite columns at points of load introduction is studied. A mechanism of force transfer and the factors...

New Steel Beam to Composite Column Connection Detail
Composite columns consisting of hollow steel tubes filled with high strength concrete with compressive strength exceeding 10000 psi (69 MPa) are being used in high-rise buildings. Connecting...

Behavior of Unbonded Braces Restrained by Reinforced Concrete and FRP
A new composite steel brace called an unbonded brace (UB) is proposed to enhance the capacity of a steel brace to carry a compressive load of almost up to the yield strength of the steel...

Steel Panel Encased R.C. Composite Shear Walls
In order to make clear the fundamental resisting mechanisms of composite shear walls, tests are carried out on the composite unit rigid frames with various infilled shear walls. Composite...

Effects of Connections on Composite Frames
This paper summarizes the preliminary findings from an experimental and theoretical study of the influence of composite connections on frame behaviour. The first part of the work included...

The Ivie Pipeline Delivering Water to West Texas
The Ivie Pipeline is a $76,000,000 - 156-mile long water pipeline being constructed in West Texas. This paper describes highlights of the planning, design, and construction phase....

Reinforced and Prestressed Concrete Pressure Pipe Diagnosis
Prestressed and reinforced concrete steel cylinder pipes are used for transmission mains, water intake lines, sewers force mains. Many collapses caused by the steel cylinder attack were...

Gas Pipeline Fitness-for-Service Investigation
A delta reclamation district's plan to add significant fill on their levee caused great concern for the integrity of a critical PG&E 22-inch (559 mm) gas transmission line which...

Pipelines Crossing Highways and Railroads by Tunneling
When new pipeline construction requires the crossing of highways and railroads, a pipeline is generally installed in pipe or tunnel linear plate encasement which has been installed by...

Analysis and Design of Direct Burial Sections of San Diego County Water Authority's Pipeline 4 Extension
The pipeline 4 extension is one of the San Diego County Water Authority's Phase I projects that will run for about 13 miles. Majority of this new pipeline will be 96 inch in steel and...

 

 

 

 