Glen Canyon Dam Spillway Tests Model-Prototype Comparison
Between August 1983 and August 1984, model and prototype tests were run on the spillway of the Glen Canyon Dam. The tests were used to design and evaluate the performance of the aeration...
Data Acquisition and Analysis of Pressure Fluctuations in Hydraulic Jumps
The paper reports on a study to procure basic data on large pressure fluctuations in hydraulic jump stilling basins. Interest in pressure fluctuations relates to: the effect of dynamic...
Computer Techniques for Acquisition and Reduction of Cross-Section Data
DuPage County, Illinois, has initiated a county-wide stormwater management program for planning and flood mitigation purposes. Field data with horizontal and vertical control are obtained...
Landfill Liner Hydraulics for Microcomputers
Two different models are presented for the study of sloping bottom liners for landfills. The first is based on the assumption that the leachate volume is uniformly distributed over the...
Water System Analysis?Modeling Hydraulics
The work described in this paper is part of the planning and design effort for expanding and improving the water supply system for St. John the Baptist Parish, Louisiana. The parish is...
Hydraulics of Broad Crested Weirs
The paper presents a general, basic discussion of the title subject. It begins with a definition for the broad crested weir and analytical concepts. Subjects covered subsequently include...
Electronic Worksheet Applications in Hydrology and Hydraulics
Spreadsheet software packages are available for virtually all micro computers in use today. Although they are quite often thought of as business tools, their usefulness as engineering...
Microprocessor-Based Data Acquisition Systems
The application of microprocessor-based data acquisition systems to laboratory experiments and field tests is discussed. The importance of the system design and hardware selection is emphasized....
Design and Calibration of a 200-Foot Model Irrigation Border with a Computer Controlled Infiltrating Bed
A physical model of an irrigation border was constructed using a 200 ft long by 2. 5 ft wide tilting flume with a 3. 5 inch deep infiltrating gravel bed. The border was partitioned into...
IIHR's Data Acquisition Systems and Their Applications
The Iowa Institute of Hydraulic Research (IIHR) has recently experienced rapid growth in number of experimental studies, in number of buildings housing these models, and in the diversity...
Measurement of Hydraulic Conductivity Variation
For a confined, sandy aquifer, the dependence of the horizontal hydraulic conductivity on the vertical coordinate has been measured using single-well tracer injection/recovery experiments....
Centrifugal Abrasion-Resistant Pumps in Intermediate Length Pipeline Systems
The success of long-distance slurry pipelines is in many cases dependent on careful preparation of the solids prior to transport. Positive displacement pumps are employed. However, for...
Series Finished Water Pumping Facilities
The paper discusses studies and design of series finished water pumping facilities for the Potomac River Water Treatment Facilities. Detailed hydraulic studies were conducted which concluded...
Cazenovia Creek Model Data Acquisition System
The purpose of the model is to reproduce river ice breakup phenomena for optimizing the design of an ice control structure. The performance of the ice control structure during a simulated...
Data Acquisition and Control for Hydraulic Models
The Waterways Experiment Station is expanding the use of computer controlled data acquisition and control equipment on a variety of hydraulic models. These systems are presently being...
What Every Hydraulic Engineer Should Know About Technical Information
This paper traces the development of indexing and abstracting of scientific literature and discusses present-day concepts of current awareness, online literature searching and numeric...
APM Configuration Concepts and Network Design
The simpler networks, along with several of the more complex variations, include the following: Single-Lane Shuttle, Single-Lane Shuttle with Bypass, Double-Lane Shuttle, Single-Lane Loop,...
Investigation of Design Criteria for APM Guideways
Designers have relied mostly on the provisions of the American Association of State Highway and Transportation Officials (AASHTO) Standard Specifications for Highway Bridges. Sometimes...
Design Criteria Impacts on Guideway Development
A highly definitive design criteria or performance specification is frequently developed for new transit systems. The criteria are intended to protect the owner's interest...
A Unique Communication System for Aerial Ropeways
The basic principles of operation of a Double Reversible Aerial Tramway are introduced. A brief note is given explaining a safety circuit or survey current used on the haul rope, since...
Return to search