Seismic Collapse Assessment of Reinforced Concrete Building
In this paper collapse analysis of reinforced concrete frame structures with and without brick infilled walls under a severe earthquake is developed. Because the structural element in...

Response of Knee-Brace-Frame Under Seismic Loading
Recently a new framing system called the Knee-Brace-Frame (KBF) has been proposed for seismic resisting structures to overcome the deficiencies of moment resisting frame and concentrically...

Welded Wire Confinement Grids
The invention of a new way to reinforce concrete using high strength welded wire grids, (WWG) increases its earthquake resistance by improved ductility and also opens the way for vast...

Seismic Strengthening of R/C Columns Using Steel Jackets
This paper presents experimental results on the use of steel collars and steel jackets as a retrofitting system to improve the seismic performance of short rectangular reinforced concrete...

Use of Eccentric Steel Bracing for Strengthening of R/C Frames
This paper presents preliminary results of ongoing research investigating the feasibility of steel eccentrically braced frames (EBFs) for seismic retrofit of reinforced concrete frames....

CenterCore Strengthening System for Seismic Hazard Reduction of Unreinforced Masonry Bearing Wall Buildings
The CenterCore technique of reinforcing unreinforced masonry walls was developed with the help of a National Science Foundation grant in 1984. The CenterCore strengthening system consists...

Earthquake Strengthening of a Twelve Story Non-Ductile Concrete Frame Building with Unreinforced Masonry Using Displacement Control Criterion
The structural concern with the Cooper Arms Apartment building when subjected to ground shaking was the in-plane and out-of-plane forces on the infill and consequences of the infill resisting...

Seismic Behavior of Weak-Column Strong-Beam Frames
An experimental evaluation of the seismic performance of moment-resisting steel frames using Weak-Column Strong-Beam joints is described. A simulated seismic response is imposed on five...

Cyclic Behavior and Seismic Design of Steel Base Plates
The objectives of this study were to conduct realistic experiments to understand cyclic behavior of steel column base plates and to develop seismic design recommendations. Six specimens...

A Comparison of the Cyclic Performance of Bolted and Riveted Connections
As part of a larger project to investigate the performance of older steel frames, a comparative study of bolted and riveted T-stub connections was conducted. The study included connections...

Some Unresolved Issues in Seismic Steel Codes
In the latest revisions of the three major U.S. seismic codes (AISC, NEHRP, UBC) some requirements can be questioned because of limited knowledge. Confining attention to conventional kinds...

Connectors for Earthquake Resistant Structures
Damage assessments from the past several earthquakes located on the northern, central and southern zones of the San Andreas Fault - Cape Mendocino: April 1992, 7.1; Loma Prieta: October...

A Wind Tunnel Study of an Aeroelastic Model of the Florida Suncoast Dome
Very large scale cable domes have been built using prestressed, high strength steel cable or strand, steel tube columns and a lightweight fiberglass skin. Geiger Engineers Florida Suncoast...

Tuned Mass Damper in Tall Building Design
Viscoelastic dN and tuned mass dampers are often used by tall building designers to control wind-induced building vibrations resulting from such phenomena as vortex shedding, galloping,...

Vortex Shedding Induced Fatigue Fracture of Mast Tower
The fracture of a pair of 60m high circular steel masts is investigated. The design criteria and fabrication practices are reviewed. The cause of failure is related to the fatigued condition...

85 Stories in Kuala Lumpur?The 5th and 6th Tallest Buildings in the World
A concrete core and cylindrical concrete tube structure provides a safe, elegant, efficient and constructible solution to the challenge of designing the world's 5th and 6th tallest buildings,...

Seismic Vulnerability and Upgrading of Nonductile Reinforced Concrete Frames Using Passive Supplemental Dampers
The effects of vulnerable details of lightly reinforced concrete frames constructed prior to the 1970s is evaluated from tests conducted of two beam/slab/column subassemblages drawn from...

Blast-Damaged Concrete Structures in Beirut
This paper describes the effect of blasting loads on structural members. It identifies predominant structural systems in war-damaged zones of Beirut and to explain typical damage mechanisms....

Steel Plate Energy Absorbers for Improved Earthquake Resistance
This paper discusses results of an combined experimental and analytical investigation on seismic response of frame structures using welded steel triangular plates as added damping and...

Response of Equipment in Structures Supported on Resilient-Friction Base Isolators Subjected to Ground Motion
In this paper, the response of equipment in structures on a particular friction-type device, the resilient-friction base isolator, is examined. The R-FBI is composed of layers of Teflon...

 

 

 

 

Return to search