An Overview of Earthquake Design Requirements at Pacific Bell
Seismic design considerations for the telephone system including outside plant and telephone equipment are discussed with emphasis placed on the requirements incorporated in the design...
Seismic Risk and Reliability of Telecommunications Systems
A general method for seismic risk analysis of telecommunications sytems evaluates by statistical means the earthquake environment and the earthquake vulnerability and effects on the system...
Energy Recovery
In Albany, N.Y. the state and city cooperated in designing and building a refuse-into-steam energy plant that has several unique features. In most such facilities, the entire plant is...
A Systematic Approach to Conducting Seismic Margin Reviews for Nuclear Power Plants
Deviations from the current codes and standards are considered acceptable in a SMR in areas where the design criteria impose significant conservatism provided the intended function of...
Response of Subsystems on Inelastic Structures
Preliminary analyses are performed to obtain insight into the seismic response of subsystems supported on simple structures that yield during severe earthquake ground motions. Current...
Seismic Qualification of Main Control Boards by Combined Mathematical Model and In-situ Modal Test
By adjusting the stiffness of the model, mode shapes and frequencies can be matched to those from the in-situ tests, thus giving a verified and representative model. With the verified...
Seismic Evaluation of Non-Seismically Designed Existing Magnox Nuclear Power Plants
Special procedures included on-site testing with a portable shake table, low vibration testing using a structural dynamics analyser, and on-site inspections. The low vibration testing...
A Summary of the Seismic Qualification Utilities Group (SQUG) Program
In 1980, the Nuclear Regulatory Commission (NRC) designated Unresolved Safety Issue (USI) A-46 to address the seismic safety of equipment in operating nuclear power plants. In 1982, the...
Update on Impact Effects in Nuclear Plants Part I?Overview and Need for Integrated Approach
In this paper, an ASCE working group on impact effects in nuclear plants updates the review of this technology contained in a five-year-old ASCE report. In Part I, an overview is given...
Update on Impact Effects in Nuclear Plants Part III?Review of Heavy Object Drop
The consequences of an accidental drop of a heavy component from a lifting device in a nuclear power plant are required to be evaluated even though the device may have been designed using...
Computer-Aided Load Monitoring System for Nuclear Power Plant Steel Framing Structures
The design of nuclear power plant steel framing structures is a long and involved process. It is often complicated by numerous changes in design loads as a result of additions, deletions...
Computer-Aided Design (Seismic Qualification) of Cable Tray Support System ? CADSTrays
A computer system for the analysis and design of cable tray hangers for nuclear power generating plants is discussed. An interactive language for the CADSTrayS was developed. Application...
Reliability Assessment of Indian Point Unit 3 Containment Structure Under Combined Loads
In the current design criteria, the load combinations specified for design of concrete containment structures are in the deterministic format. However, by applying the probability-based...
Sensitivity of Peak Dynamic Responses to Input Factors
Responses have been calculated for the Zion Unit 1 plant, using the SSMRP computer code SMACS, as part of the seismic probabilistic risk assessment performed by the Seismic Safety Margins...
Seismic Evaluation of Reinforced Masonry Walls
Masonry walls in operating nuclear plants are in many cases found to be overstressed in terms of allowable stresses when evaluated using current seismic design criteria. However, experimental...
Seismic Capacities of Masonry Walls at the Big Rock Point Nuclear Generating Plant
An evaluation to determine the ability of selected concrete block walls in the vicinity of essential equipment to withstand seismic excitation was conducted. The seismic input to the walls...
The Use of Joint Reinforcement in Qualifying Masonry Walls in Nuclear Power Plants
Wire joint reinforcement has been traditionally used in block masonry walls for crack control and to provide continuity for multiple wythe walls. In a number of nuclear power plants, vertically...
Probabilistic Seismic Analysis of a Nuclear Power Plant Steel Containment
Concern for the safety of nuclear power plants has motivated efforts to determine the statistical characteristics of the seismic resistance of steel containments under various types of...
Desin Control for Nuclear Power Plant Modifications
Modifications to operating nuclar power plants which impact structural components must be performed in a manner that is consistent with the licensing basis and technical specifications...
Microcomputer Applications for NSSS Data Package Review
Associated with each component of a Nuclear Steam Supply System are the necessary supporting documents which demonstrate compliance with applicable codes, specifications and design criteria....
Return to search