Hysteretic Behavior of Composite Diaphragms
Floor systems constructed with steel-deck-reinforced concrete are described. When used to resist lateral loads these systems are referred to as diaphragms. A description of a test arrangement,...
Vibration Tests of Reservoir Structures Outlet Tower and Footbridge
This paper presents a field test procedure used in determining the dynamic properties of an outlet tower and footbridge for a major reservoir. Such factors as virtual water mass, soil-structure...
Some Aspects of Bridge Instrumentation
This paper provides some guidelines about the proper arrangement of strong motion instruments for the proper assessment of some particular phenomena that have been either observed in past...
Floating Bridges in Short-Crested Random Seas
Four large concrete floating bridges located in Washington State have been the subject of extensive analytical modeling for dynamic response to storm waves. The dynamic analysis of the...
Refinements in Pseudo-Dynamic Test Procedures
One of the major concerns in seismic testing is whether the loading conditions imposed on a structure adequately represent those that might occur during a major earthquake. Response simulation...
Response of the San Juan Bautista 156/101 Bridge to the 1979 Coyote Lake Earthquake
Strong-motion accelerograms are used to examine the response of a multiple-span highway bridge to earthquake loading. Estimates of modal frequencies and damping values for the first two...
Seismic Behavior of Long-Span Cable-Stayed Bridges
Special features of the earthquake-response analysis of cable-stayed bridges, subjected to multiple-support excitation, are presented including a basis for calculation of seismic forces...
Seismic Response Analysis of Two Major Bridge Structures
The seismic response analyses of two major bridge structures have been conducted. In these two bridges, portions of the piles are either submerged in the water or free-standing within...
Performance of Existing Buildings: Results of Benchmark Structure Analyses Performed in U.S.-Japan Workshops
In response to the need for better understanding of current safety evaluation methodologies, three U. S. -Japan workshops have been conducted on the evaluation of the performance of existing...
Strengthening of a Multi-Story Building with Deflection Constraints
Occasionally the existing structural or nonstructural systems of a building being strengthened require the imposition of deflection constraints or limits in order to avoid an undesirable...
Regional Risk Assessment of Existing Buildings
This paper describes current research underway at Stanford University designed to develop a methodology for determining high risk buildings in a region. The work involves developing a...
On Reliability-Based Structural Optimization for Earthquakes
Previous studies of reliability-based structural optimization have been extended in order to investigate the applicability of the linear statistical model in cases where random parameters...
Seismic Restraint of Hazardous Process Piping
The lack of appropriate guidelines for the design and installation of hazardous process piping in industrial facilities has created a potentially dangerous situation. Process piping carrying...
Three Phase Design for Wind Loads on Structures
The successful design of a structure requires three phases of work. These phases are: conceptual design, design development and design verification. The conceptual design is undertaken...
Changes in Bridge Deck Flutter Derivatives Caused by Turbulence
This paper discusses some of the results of a wind tunnel study that tested the aeroelastic stability of section models in smooth and gusting flow. Wind gusts several times longer than...
Slab Participation in Frames under Lateral Loads
A unique opportunity to study slab participation was afforded by the U. S. -Japan Cooperative project on large scale testing. The data obtained from the full-scale 7-story building tested...
Evaluation of Seismic Strengthening of an Existing Building Using Base Isolation
This paper summarizes a study performed by Englekirk and Hart, Inc. to evaluate the feasibility of using base isolation to seismically upgrade an existing highrise building. To realize...
Earthquake Response of Five Story Reinforced Concrete Masonry Test Building
In 1986, a full-scale five story reinforced masonry test building is to be constructed in the Japan Building Research Institute Large-Scale Structure Test Laboratory, and through 1987...
A Discrete Model for the Estimation of the Elastic Abutment Stiffness
The purpose of this paper is the presentation of a simple method for the estimation of the abutment stiffness. In this method, the abutment is represented as a uniform rigid plate with...
Modeling for Finite-Element Soil-Structure Interaction Analysis
The modeling for finite-element soil-structure interaction analysis for embedded structures is evaluated in an attempt to resolve the issue related to the elevation at which design ground...
Return to search