Pipeline Explodes, Two Dead, 31 Injured, 11 Homes Destroyed
A high pressure pipeline in a suburb of San Bernardino, California exploded in a deadly fireball on May 25, 1989. Damaged as a result of a train wreck several weeks earlier, or by the...

Corrosion Protection of Cast Iron and Ductile Iron Pipe, San Diego, California
This paper addresses the use of a loose unbonded plastic covering polyethylene encasement for protection of cast and ductile iron pipe in an extremely corrosive soil. The case study in...

Measured Performance and Numerical Analysis of Buried Pipe
This study shows that the behavior of a soil pipe system can be assessed by a nonlinear elasto-plastic finite element analysis. The results of numerical calculations are compared to the...

Design of Drainage Pipes Below Landfills
Drainage pipes are an essential component of landfills. Even though their embedment conditions differ substantially from those of pipes for municipal utilities near the ground surface,...

FE Elastic Analysis of Measured Earth Pressure on Buried Rigid Pipes in Centrifuged Models
FE elastic analyses of earth pressure on buried rigid pipes yielded results that agreed well with the earth pressure measured in 42 centrifuged models, confirming both the reliability...

Evaluation of Combined Load Tests of Prestressed Concrete Cylinder Pipe
Combined load tests of prestressed concrete cylinder pipe, presented by Tremblay in the proceedings of this conference, are analyzed. Data gathered during the tests includes first visible...

The Effect of Compaction on Buried Flexible Pipes
This contribution presents an analysis of the installation of flexible pipes in granular soil. The deformation of the pipe cross section is measured in field and laboratory tests. It is...

Designing Vitrified Clay Pipe Systems with EASE
NCPI has developed a computerized trench load design program which provides a broad and complete spectrum of design options which will enable engineers and contractors to safely design...

Analysis of Alternative Pipe Materials for a Major Public Water Agency
A major southwestern public water agency has historically specified the exclusive use of prestressed concrete cylinder pipe (PCCP) for large diameter water transmission mains. Due to the...

A Look Back in Time to Verify Life Cycle Cost Analyses
The proper engineering design of any hydraulic structure requires consideration of different but interrelated fields of: 1) Planning, 2) Hydrology, 3) Hydraulics, 4) Structural, 5) Installation,...

Landfill Gas Pipe Selection and Installation
Sanitary landfills present a unique array of pipe selection and installation criteria when designing landfill gas (LFG) control and recovery systems. Factors that must be considered include...

Twin Pipeline Crossing of the Fraser River
A new creek water supply was developed for the communities of Mission and Matsqui, British Columbia, Canada, in the early eighties. Over 60 kilometres of 450 mm to 900 mm diameter ductile...

Relining of Jordan Aqueduct, Reach 3
As pipelines approach their life expectancy, they may need to be replaced. Or in some instances, replacement is needed much sooner due to defective pipe. Normal replacement operations...

Field Experiment on Behavior of Continuous Water Main with a Miter Bend
A field experiment was conducted to investigate behaviors of a buried continuous steel water main with a 90-degree miter bend subjected to internal pressure and ground settlement. Deformations...

Keeping Lifelines Alive
There were no city water supplies to fight the fires in San Francisco after last year's earthquake. The fires were brought under control because of an historic auxiliary water...

Development of the Engineered Barriers for the Deep Geological Disposal of High-Level Radioactive Waste
Vitrified waste, overpack and buffer material are under research and development as engineered barriers in the deep geological disposal system of high-level radioactive waste. Static leach...

Removal of Scale from Potable Hot Water Systems by Carbon Dioxide Injections
An innovative method for inplace scale removal has been developed and demonstrated. Injection of carbon dioxide gas into a piping system can lower the pH of the hot water and remove or...

Predicting Watermain Breakage Rates
Recent studies on water main breakage have shown significant spatial and temporal clustering in the breakage pattern. The methodology described in the paper provides the basis for a prediction...

Urban Drainage Pipe Systems: Failure Diagnosis and Rehabilitation Planning
A Task Committee on Failure Diagnosis and Rehabilitation of Urban Drainage Infrastructure has been organized by the Urban Water Resorces Committee of the Water Resourcs Planning and Management...

The New Generation of Pipeline Rehabilitation
The new advancements in pipelines reconstruction technologies now permit total sewer system rebuilding of collectors, drainlines, manholes, service laterals, and force mains without excavation....

 

 

 

 