Conservativeness in Hydraulic Engineering Studies
Hydraulic engineers routinely make a variety of assumptions during the course of a study. Assumptions, once made, usually become incorporated into the fabric of the study and are seldom...
Stability Criteria for Revetments
A simplified 'black box' approach is presented for a number of revetment systems for banks and shore protection. The design criteria, based on the physical similarity...
The Influence of Uniformity on Riprap Stability
Studies have shown that size uniformity influences the stability of riprap. The ratio of fractional sizes of the riprap mixture, D60/D10,...
Design and Construction of Soil-Cement Drop Structures
Soil-cement has been used as an effective and economical slope protection material for embankment dams and stream banks. This paper describes the use of soil-cement in the construction...
Characteristic Deformation of Alternate Bars Due to Low Flow
Experiments on the formation of a small meander-channel at low stage are conducted by supplying a proper discharge on initial bed of alternate bars that have been formed in experimental...
Uncertainty Estimates for Rainfall-Runoff Model
Almost all rainfall-runoff link-node models in use today involve the subdivision of the catchment into smaller areas, linked together by a system of channel links. These 'link-node'...
Evaluation of the ARS Low Drop Grade Control Structure
The ARS low drop grade control structure was developed by Little and Murphy to provide efficient energy dissipation and effective grade control for streams in northern Mississippi. The...
Mt. Elbert Pumped Storage Trashrack Failure
The failure of three trashrack sections for unit 2 at the suction-draft tube intake occured after one year in service. However, the trashracks for unit 1 had five years of service with...
Guard Gate Tests at Tieton Dam
The emergency gate hoist system on the guard gates at Tieton Dam, near Yakima, Washington, was tested as part of the United States Bureau of Reclamation Safety Evaluation of Existing Dams...
Characteristics of the Flood Release-Induced Vibrations with Qianshui Thin-Arch Dam
In this article the prototype observations and design analyses are described regarding the flood release-induced vibrations of the Qianshui thin-arch dam and its foundation; and their...
Development of a Computer Aided Decision Process for Channel Rehabilitation and Watershed Enhancement Techniques
To assist the engineer in planning and design of channel stabilization measures, an expert system (CADWET) was developed using a commercially available expert system shell program. The...
Pump Selection Program and a Better User Interface
Numerous highly innovative computer solutions to engineering problems are of little use to the practicing engineer because these programs are not supported by adequate user interface....
Comparison of Flush and Chamber Mounted Dynamic Pressure Transducer
Modeling of hydraulic structures often includes the measurement of dynamic pressure fluctuations. The accuracy of the pressure measurements depends upon the geometry of the tap. Flush...
Redondo Beach King Harbor Model Studies, California
Redondo Beach King Harbor frequently experiences damage when large winter waves occur in conjunction with high water levels. Damages consist of revetment failure, land erosion, flooding,...
Low-Head Drop Structure Hazards: Modeling of an Abrupt Drop Boat Chute
Low-head drop structures are dangerous for navigational and recreational boating in rivers. In an effort to reduce drowning hazards at low-head river drop structures, a boat chute bypass,...
Cumulative Impacts Analysis on a Midwest Fluvial System
The US Army Corps of Engineers recently completed an analysis of the cumulative impacts of erosion control structures on the Platte River in Nebraska. This was done in response to concerns...
Effects of Low Drop Grade Control Structure on Bed and Bank Stability
The channel response upstream of a low drop grade control structure was documented using field investigations, analysis of the engineering properties of bank materials, and repeat cross...
Stabilization of an Alluvial Channel in an Urbanized Area
Grade stabilization structures have been used for many years to control degradation of alluvial stream in the southwest. These structures result in reducing the gradient of the stream...
Mechanical Aspects of Intake Gates at John Hart Dam
As part of the John Hart Dam rehabilitation program completed in 1988, six new intake gates complete with guides and hydraulic operators were installed replacing the existing gates and...
Model Tests for Design of Vibration-Free Gates
Experimental results are presented of hydraulic forces acting on an underflow gate. Underflow gate is a socalled bluff body and a review of the mechanism of vibration caused by separation...
Return to search