Direct Filtration of High Turbidity Water Using Contact Flocculation
It is shown that the system of bed contact flocculation followed by standard dual media filters provides a viable alternative to both conventional as well as direct filtration, particularly...
Treatment Plant Comparisons in Removing Molecular Weight Fractions of THM Precursors
This paper describes the performance of several types of water treatment plants in removing various molecular weight fractions of natural occurring aquatic organic matter, some of which...
Direct Filtration of Colored Water Supplies
The effects of raw water quality, chemical treatment, and filtration variables on the performance of direct filtration are examined. Cationic polyelectrolytes as sole coagulants are effective...
Optimization of Design and Operating Parameters for Single-Media, Unstratified-Bed Filters
The potentially successful use of filters containing large grain-size single media for water filtration has prompted investigation of the parameters controlling the performance of these...
Computer Simulation of Lime-Soda Softening of Cooling Waters
A computer model is developed to simulate the process of lime-soda softening of cooling waters. Results from the model are compared with those from a laboratory experimental study using...
Development of a Simplified Nitrogen Mass Balance Model in a Macroalgae Dominated System
A seasonably variable nitrogen uptake rate has been established for Ulva in Mumford Cove, Conn. This rate has been verified using three separate water quality analyses each of which assume...
PCB Contamination of a Mass. Harbor: Technical Challenges for a Remedial Solution
The highest priority uncontrolled site in Massachusetts, the New Bedford Harbor Superfund site, is contaminated with high concentrations of PCBs. The magnitude and nature of contamination,...
In-Plant Testing for Evaluating Aeration Systems
In the fall of 1984, ASCE published a standard, Measurements of Oxygen Transfer in Clean Water. The standard, if used by the industry, should simplify evaluation of alternative aeration...
A New Approach to Activated Sludge Plant Design
Activated sludge plants are designed on the basis of stationary tests at laboratory scale for constant organic loads and constant input flows. From these tests the kinetic parameters are...
Measurement of Activated Sludge Rheology
Rheological measurements provide fundamental information on the physical properties of activated sludge. Such properties influence the behavior of activated sludge in wastewater and sludge...
Understanding Secondary Clarifier Behavior
The author has developed a graphic procedure for analyzing the hydraulic behavior of settling tanks. Data have been used in numerous cases to devise low cost in-tank and external improvements...
Impoundment Design for Precious Metal Tailings
An engineering study and design of impoundments for the disposal of mill tailings in central Nevada is presented. Mill process waste is generated as flotation tailings and cyanide residue....
Field Scale Solidification/Stabilization of Hazardous Wastes
The selection of appropriate remedial action measures only takes place after a full evaluation of all feasible alternatives. An alternative to off site disposal is solidification/stabilization...
Variable Leachate Treatment System: A Cast Study
This paper explores the experience of the authors in collecting data and designing leachate collection and treatment facilities at municipal sanitary landfills over the last several years....
Detection of Leakage Through Subsurface Barriers Using Guided Acoustic Waves
The primary method for preventing hazardous liquid and leachates from entering the groundwater is the use of a physical barrier. These barriers are susceptible to a number of mechanisms...
A Rule-Base Inference System for Liner/Waste Compatibility
Determining the chemical compatibility of a liner material for containment of wastes rests mainly on the application of expert opinion to interpret the results of short-term immersion...
Evaluation of PVC Bottom Linear From an Existing Landfill Located in a Subtropical Climate
Remedial action to curtail leachate seepage on a sanitary landfill located in a subtropical climate included the attachment of new PVC liner to an existing 20 mil PVC liner which has been...
Anaerobic Treatment of Phenol: Degradability, Toxicity and Kinetics
Anaerobic biodegradation of phenol was demonstrated at up to 1000 mg/L in batch serum bottle studies and 1900 mg/L in anaerobic filters. In batch serum bottle studies, concentrations of...
Treatment of the Wastewater From the Alkaline Cooking of Maize in an RBC System
The liquid waste resulting from cooking and washing of maize is called nejayote or nexayote. The soluble COD concentration of this waste ranges from 10,000 to 20,000 mg/l. In an effort...
Land Treatment of API Separator Sludge
An extensive research project was undertaken to establish design and operational guidelines for treatment of oily sludge using land treatment systems. Forty-five test plots were established...
Return to search