Seismic Behavior of Weak-Column Strong-Beam Frames
An experimental evaluation of the seismic performance of moment-resisting steel frames using Weak-Column Strong-Beam joints is described. A simulated seismic response is imposed on five...
Fluid Viscous Damper for Improving the Earthquake Resistance of Buildings
Experimental results are presented which demonstrate that the use of fluid dampers as add-on devices in moment resisting frames substantially increases damping and reduces seismic story...
Evaluation of Seismic Isolation Schemes for a Historic Building
The U.S. Court of Appeals Ninth District building originally completed in 1905 with an expansion in 1933, suffered damage during the 1989 Loma Prieta earthquake. The building is currently...
Nonlinear Dynamic Analysis of Single Point Moored Buoy Under Wave and Current Loadings
In this study, a single point moored spherical buoy under wave and current loadings is analyzed in the time domain considering time memory effects. Geometric nonlinearity of the mooring...
A Shear Transfer Model for Floor-To-Wall Connections in Concrete Masonry Structures
Based upon experiments conducted at the Univ of California, San Diego (UCSD) on floor-to-wall connections in concrete masonry structures, a constitutive model was developed for the overall...
Analysis of Masonry Walls with Smeared and Discrete Crack Models
To design modern reinforced masonry structures for seismic loads and to evaluate the seismic safety of existing unreinforced masonry buildings, the shear resistance of masonry shear walls...
Behavior and Design of Angle Connections Subjected to Cyclic Axial Force and Shear
The objectives of this study were to establish cyclic behavior of double angle shear connections subjected to axial load and to develop design recommendations. Five cyclic tests of double...
Interaction Between Beam and Steel Connections
The overall objective of the investigation is to study the behavior of a particular steel connection type, flush end plate steel connections, subjected to shear, axial forces, and possibly...
The Effect of Nonlinear Drag PSD on Fatigue of Compliant Offshore Structures
Structural fatigue damage induced by random ocean wave loading on a compliant type of offshore structure is considered. The nonlinear wave force is modeled by the Morison equation and...
Flexural and Shear Behavior of Combined Concrete and Graphite Epoxy Beams
An experimental and analytical study of six graphite composite beams are presented. Four of the beams incorporated a reinforced concrete slab. The composite action and the effect of concrete...
The Innovative Concept of Semi-rigid Composite Beam
This paper discusses invention and development of a new type of composite beam called 'Semi-rigid Composite Beam.' This new type of beam is expected to behave better than presently used...
Inspections, Evaluations and Modifications for Corps of Engineers Dams
The Corps of Engineers owns and operates 580 dams in the United States. As these dams become older (199 are over 50 years old), dam safety and modifications play an increasing role in...
Three-Dimensional Stability Analysis of Carpenter Dam
This paper describes the three-dimensional stability analysis of Carpenter Dam. The presence of keyed construction joints between dam monoliths at Carpenter Dam can significantly affect...
In Situ Testing Performed at Jackson Lake Dam
Jackson Lake Dam was rehabilitated from 1986 to 1988 to increase seismic stability. Final foundation improvements consisted of dynamic compaction and mixed inplace soil cement columns....
Prediction of Embankment Dam Breaching for Hazard Assessment
Downstream hazard assessments for dams require prediction of 1) whether a breach could form, and 2) the hydraulic characteristics of the breach for use in calculations of discharge and...
Roller Compacted Concrete for Embankment Overtopping Protection
In the first National Dam Safety Inventory and inspection performed by the Corps of Engineers, the majority of deficiencies found were related to the inability of the project to retain...
Construction of CCM Overtopping Protection on Three Parkway Dams
Cellular concrete mat (CCM) systems have been installed as overtopping protection on three small embankment dams along the Blue Ridge Parkway. Based on field tests by others and on the...
Graham Lake Dam Remedial Measures Project
Graham Lake Dam consists of a 550-foot long earth embankment and an 80-foot long concrete spillway. Several concerns were identified during project inspections including limited spillway...
Economical Solution for Flood Overtopping Potential at Senator Wash Dam
A breach analysis of North Dike for overtopping with the crest modified to the lower elevation was required to ensure the breach discharge would be adequate to prevent overtopping of Senator...
Bureau of Reclamation Experience with Innovative Solutions to Increased Design Floods
Over the last several decades advances in the hydrologist's ability to estimate floods have resulted in increases to the design floods for many existing drainages. As with other dams throughout...
Return to search