Full Scale Caisson Load Test for the Milwaukee Center
Top-down procedures were proposed to construct four basement levels for a major high-rise building development in Milwaukee, Wisconsin. Drilled caisson foundations were the preferred means...
Drilled Shafts?A Database Approach
A database of 43 drilled shaft load tests of high quality has been developed to study parameters that affect the axial behavior of drilled shafts and methods of analysis to predict axial...
A Lateral Load Test on Seven Foot Diameter Caissons
Seven foot (2.1 m) diameter caissons (drilled shafts) were designed to support a mainline eastbound bridge and an off-ramp of Interstate Highway 70 in Glenwood Canyon, Colorado. A lateral...
Interpretation of Load Tests and Drilled Shafts?Part 3: Lateral and Moment
Existing interpretation methods for lateral and moment load tests are reviewed critically, and a qualitative and quantitative comparison is made for selected methods. A new method is proposed...
Nondestructive Testing of Deep Foundations with Sonic Methods
Nondestructive testing and evaluation (NDT&E) of deep foundations with three sonic methods is discussed. Case history investigations described include test records from drilled...
Geophysical and Nuclear Methods for Non-Destructive Evaluation of Caissons
Non-destructive testing techniques were used to confirm the concrete integrity on the caisson foundations for the 45-story Ohio Corporate Headquarters building in Cleveland, Ohio. The...
Bearing Capacity of Shallow Strip Foundation on Strong Clay Underlain by Weak Clay
Laboratory model test results for the ultimate bearing capacity of shallow strip foundations supported by a stiff clay layer underlain by a weaker clay layer have been presented. The model...
Rectangular Footing on Nonhomogeneous Elastic Half Space
The problem of a rectangular footing or a strip footing on a nonhomogeneous elastic half space is studied in this paper. The medium is assumed to be isotropic with a variable shear modulus...
Performance of a Large Ribbed Mat on Cohesive Soil
The performance of a 678-ft by 304-ft (207-m by 93-m) ribbed concrete mat was studied to provide improved soil input parameters for design. The mat was constructed on a low plasticity...
Bearing Capacity of Shallow Foundation on Granular Column in Weak Clay
Laboratory model tests results for the ultimate bearing capacity of shallow rectangular foundations supported by granular columns made in weak clay have been presented. In all cases, the...
Interpretation of Instrumented Driven Steel Pipe Piles
This paper presents the results of a series of studies on the behavior of driven close-ended steel pipe piles. Extensive field explorations and geotechnical analyses have been carried...
Issues in Evaluating Combined Repeated Loading of Deep Foundations
The capacity and load/displacement response of deep foundations subjected to combined modes of repeated loading can be significantly different from the response under single (axial or...
Pile-Drilled Caisson Combination for Foundation of High Rise Building
The analysis and evaluation of several alternatives for foundations of a high rise office building is presented, which resulted in the selection of a combination of high capacity piles...
Cost Effective Pile Foundation Supports Fast Track Paper Mill
This paper decribes the generalized subsurface conditions, pile evaluation and load test program, pile and piling contractor selection, production pile installation, and quality assurance...
Combination Drilled Shaft and Driven Pile Foundation for a High-Rise Building
A case history is presented which discusses the design and construction of a combination drilled shaft and driven pile foundation which supports a high-rise in San Francisco. Drilled piers,...
Performance of a Building Foundation Designed to Accommodate Large Settlements
The Eastern Airlines shuttle terminal at LaGuardia Airport in New York City is supported on spread footings founded in an incinerated refuse fill which overlies a deep deposit of slightly...
Special Bedrock Conditions and a Foundation Project in Greater Boston
In the greater Boston area the argillite bedrock and/or the overlying glacial till provide suitable support for a wide range of foundation systems, including high capacity end-bearing...
Long Term Performance of High Rise Mat Foundation
The vertical movement of the foundation soils for a multi-story high rise office tower was monitored during foundation excavation, tower construction and the 25-year in-service period...
Complex High-Rise Foundation Design and Construction
The substructure design and construction of a 60 story office tower in downtown Chicago is described. The presence of existing belled caissons on hardpan required use of filtered dewatering...
A New Combined Footing and Drilled Shaft Foundation Design
A conventional belled caisson foundation installation in glacial till to support a suburban Chicago 10-story office building was stopped when test caissons revealed excessive water-bearing...